About GEMTECH G2000-10 MM Differential Pressure Gauge 0-10 MM

GEMTECH G2000-10 MM Differential Pressure Gauge 0-10 MM
Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel,with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70 (21 (3% on -0,and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model |
Description |
| G2000-100MM |
Differential Pressure Gauge,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
Differential Pressure Gauge,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
Differential Pressure Gauge,Range 0-150 MM W.C. |
| G2000-15MM |
Differential Pressure Gauge,Range 0-15 MM W.C. |
| G2000-200MM |
Differential Pressure Gauge,Range 0-200 MM W.C. |
| G2000-250MM |
Differential Pressure Gauge,Range 0-250 MM W.C. |
| G2000-25MM |
Differential Pressure Gauge,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
Differential Pressure Gauge,Range 0-300 MM W.C. |
| G2000-50MM |
Differential Pressure Gauge,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
Differential Pressure Gauge,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
Differential Pressure Gauge,Range 0-80 MM W.C., Minor Divisions 2.0.
|
Additional Information:

Versatile Industrial Pressure MonitoringThe GEMTECH G2000-10 MM Differential Pressure Gauge is engineered for accurate gas pressure measurement across critical industries. With its broad scale range and robust construction, it adapts to diverse operational environments. The dual-tap design offers installation flexibility, while the large, clear dial ensures at-a-glance reading. Back-mounting and lightweight design further enhance its usability in complex industrial setups.
Precision and Reliability in Every MeasurementThis gauge promises precision, delivering accuracy within 2% of the full scale for most ranges. Its alloy pointer and durable plastic housing withstand industrial wear and tear. Suitable for various pressure units, it brings reliability to both routine and demanding applications. The analog interface requires no external power source, ensuring seamless, continuous operation.
FAQ's of GEMTECH G2000-10 MM Differential Pressure Gauge 0-10 MM:
Q: How does the GEMTECH G2000-10 MM Differential Pressure Gauge measure gas pressure?
A: The GEMTECH G2000-10 MM Differential Pressure Gauge uses a differential mechanism to measure the pressure difference between two points in a gas system. The result is displayed on a 4-inch analog dial, making it easy to monitor changes accurately.
Q: What are the primary industrial applications for this gauge?
A: This device is designed for use in pharmaceuticals, power plants, cement plants, steel plants, fertilizer production, and textile industries, where accurate monitoring of low gas pressures is essential for safety and efficiency.
Q: Where can this pressure gauge be installed and how is it mounted?
A: The gauge can be installed on equipment using its 1/8-inch female NPT threaded taps, which are available both on the side and the back for installation flexibility. Its back-mount type allows easy fitting into control panels or machinery surfaces.
Q: When should calibration or maintenance be carried out on this gauge?
A: Calibration and maintenance should be performed based on usage frequency, environmental conditions, and industry regulations-typically annually or as recommended by company protocols-to maintain measurement accuracy.
Q: What pressure units can be read on this gauge, and what is the benefit of multi-scale capability?
A: The gauge supports reading in MM WC, CM, PAC, KPA, INCH, PSI, and MBAR. This multi-scale capability allows users to work with whichever unit suits their process needs, reducing the need for unit conversions and ensuring operational accuracy.
Q: How does the accuracy benefit industrial operations?
A: With up to 2% full-scale accuracy, the gauge provides reliable and precise measurements, helping operators detect pressure anomalies early, maintain process control, and avoid downtime or hazards.
Q: What is the process for connecting the gauge to a system?
A: Connect the gauge by attaching the high and low-pressure ports to the respective points in the gas system using the 1/8-inch NPT threads. Ensure proper sealing to prevent leaks, then monitor pressure differences directly on the analog dial.