Series G2000GEMTECHDifferential Pressure Gaugesare Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature- -21 140 -6 60
- Rated Pressure-20 inHg30 inHg (-68103KPa)
- Overpressure -Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections -1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing- Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand168 Hour Salt Spray Corrosion Test
- Accuracy- i2% of full span at 70 (21 (i3% on -0, and i4% on -00)
- Range-20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive AndNegative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH ByModel NumberPopularity
- FILTER BY
- Range -MM Of Water
| Model |
Description |
| G2000-100MM |
Differential Pressure Gauge,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
Differential Pressure Gauge,Range0-10 MM W.C.,Minor Divisions.20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
Differential Pressure Gauge,Range0-150 MM W.C. |
| G2000-15MM |
Differential Pressure Gauge,Range 0-15 MM W.C. |
| G2000-200MM |
Differential Pressure Gauge,Range 0-200 MM W.C. |
| G2000-250MM |
Differential Pressure Gauge,Range 0-250 MM W.C. |
| G2000-25MM |
Differential Pressure Gauge,Range0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
Differential Pressure Gauge,Range0-300 MM W.C. |
| G2000-50MM |
Differential Pressure Gauge,Range0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
Differential Pressure Gauge,Range0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
Differential Pressure Gauge,Range0-80 MM W.C., Minor Divisions 2.0.
|
Additional Information:

Precision Measurement for Critical Applications
GEMTECH's Differential Pressure Gauge provides accurate readings with an error margin as low as 2% of full scale for the -HA model 1. Its reliability ensures continuous monitoring in environments where pressure differentials can impact system performance or safety, such as pharmaceutical clean rooms, power plants, and manufacturing facilities.
Durable and User-Friendly Design
This gauge is constructed from strong metal alloys, paired with a robust plastic dial and an easy-to-read 4-inch face. Its light weight (550 grams) and versatile mounting options (back mount) make installation simple and efficient, catering to various industrial settings and equipment panels.
FAQ's of GEMTECH Differential Pressure Gauge Range 6-0-6 MM:
Q: How do I install the GEMTECH Differential Pressure Gauge for optimal accuracy?
A: To install the GEMTECH Differential Pressure Gauge, use the 1/8" female NPT high and low pressure taps provided on both the side and back. Choose the appropriate set based on your mounting preference. Ensure the gauge is mounted at eye level for the clearest readings and connect the pressure lines securely to avoid leaks, maintaining a stable environment near 70F (21.1C) for best accuracy.
Q: What range and accuracy levels does this gauge provide?
A: The GEMTECH Differential Pressure Gauge covers a range of 6-0-6 MM WC, with accuracy levels of 2% FS for the -HA model 1, 3% (-HA 1.5%) on -0, -100PA, -125PA, -10MM, and 4% (-HA 2%) on -00, -60PA, -6MM-throughout the range at 70F (21.1C). These specifications make it highly suitable for industrial applications requiring reliable differentiation of pressure.
Q: When should I use this differential pressure gauge in my process?
A: Use this gauge whenever precise monitoring of pressure differences is essential, such as in filtration systems, clean room validation, or air/gas flow control. Its use is recommended during regular maintenance checks, process optimization, and whenever troubleshooting pressure-related issues in plant operations.
Q: Where can this pressure gauge be used effectively?
A: This gauge is ideal for pharmaceutical facilities, power plants, cement, steel, fertilizer, and textile factories. Its versatility also allows it to be used in other industrial settings that require reliable differential pressure monitoring, such as HVAC systems, laboratories, or manufacturing clean environments.
Q: What is the process for calibrating or maintaining this gauge?
A: Calibration should be carried out using a certified pressure standard at periodic intervals indicated by your facility's maintenance schedule. Regularly inspect the gauge for signs of mechanical damage or debris in the pressure taps, and ensure connections remain leak-free. If readings appear inconsistent, recalibration or professional servicing might be necessary.
Q: What are the key benefits of using the GEMTECH Differential Pressure Gauge?
A: Key benefits include high accuracy, robust alloy construction, broad compatibility with different scale units and pressure systems, and straightforward installation. These features ensure consistent performance, reduced downtime, and reliable operation across a variety of demanding industrial environments.