About GEMTECH Differential Pressure Gauge Range 50-0-50 Pascal

GEMTECH Differential Pressure Gauge Range 50-0-50 Pascal
Series G2000, GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of filter, wind speed, furnace pressure, differential pressure of pore plate, the pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime, They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely. The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature - -21 140 6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa).
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70 21 3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure, Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges. Minimum is 0-60 Pa And Maximum is 0-21-KPa.
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
- FILTER BY
- Range - Pascals - Zero Center
| Model |
Description |
| G2300-100PA |
Differential Pressure Gage, Range 50-0-50 Pa,Minor Divisions 2.0,Calibrated For Vertical Scale Position. |
| G2300-120PA |
Differential Pressure Gage, Range 60-0-60 Pa,Minor Divisions 2.0. |
| G2300-250PA |
Differential Pressure Gage, Range 125-0-125 Pa,Minor Divisions 5.0. |
| G2300-500PA |
Differential Pressure Gage, Range 250-0-250 Pa,Minor Divisions 10.0. |
| G2300-60PA |
Differential Pressure Gage, Range 30-0-30 Pa,Minor Divisions 1.0,Calibrated For Vertical Scale Position. |
Additional Information:
Comprehensive Pressure MeasurementEngineered for accuracy, the GEMTECH Differential Pressure Gauge evaluates gas pressure differences in a range of industrial environments. Its wide scale and analog display facilitate easy and reliable readings, crucial for process optimization and safety compliance.
Durable Construction for Demanding FacilitiesHoused in a robust metal alloy body with a 4-inch dial face, the gauge withstands challenging conditions in plants such as steel, cement, and fertilizers. The plastic dial and alloy pointer ensure longevity and minimal wear during extended operation.
Flexible Installation and ConnectivityEquipped with back mounting and dual pairs of 1/8" NPT female taps on both side and back, the gauge adapts to diverse installations. This versatility streamlines integration in existing industrial systems and supports rapid maintenance or replacement.
FAQ's of GEMTECH Differential Pressure Gauge Range 50-0-50 Pascal:
Q: How is the GEMTECH Differential Pressure Gauge typically installed in industrial applications?
A: The GEMTECH Differential Pressure Gauge can be mounted using the back mount option and connected via 1/8" female NPT taps, with pairs located on both the side and back for flexible plumbing in various setups.
Q: What gases can be measured with this pressure gauge?
A: This differential gauge is specifically designed to measure the pressure of various gases used in industries such as pharmaceuticals, power plants, cement, steel, fertilizers, and textiles.
Q: When should this gauge be used instead of a digital gauge?
A: The GEMTECH analog gauge is preferred in situations where line power is unavailable, quick visual checks are needed, and environments demand a durable, straightforward device with minimal maintenance.
Q: Where is this differential pressure gauge most beneficial?
A: This gauge is highly effective in settings that require precise low-pressure monitoring, such as clean rooms, HVAC systems, process gas lines, and filtration monitoring in manufacturing plants.
Q: What is the measuring range and which units are supported?
A: The gauge measures differential pressures from 50 to 0 to 50 Pascal. Its dial is marked in multiple units, including MM WC, CM, PAC, KPA, INCH, and PSI, allowing for versatility in a broad spectrum of industrial standards.
Q: How does the dual tap system enhance usage and maintenance?
A: Having duplicate high and low pressure taps on both the side and back enables more convenient installation, pressure source selection, and easier access for troubleshooting or calibration.
Q: What are the benefits of using this gauge in an industrial setting?
A: Industrial users benefit from reliable, real-time monitoring and enhanced process safety, helping detect anomalies quickly and maintain regulatory compliance across a variety of sectors.