About GEMTECH Differential Pressure Gauge Range 0-5 Inches

GEMTECH Differential Pressure Gauge Range 0-5 Inches
Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine,Resistance of Filter,Wind Speed, Furnace Pressure,Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System.Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment.There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" Female NPT Duplicate High And Low Pressure Taps - One Pair Side And One Pair Back
- Housing - Die cast aluminum case and bezel, with acrylic cover,Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70 (21 (3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
- FILTER BY
- Range - Inches of Water
|
Model
|
Description
|
|
G2000-0
|
Differential Pressure Gauge,Range 0-0.503 w.c., minor divisions .01, calibrated for vertical scale position.
|
|
G2000-00
|
Differential Pressure Gauge,Range 0-0.253 w.c.,minor divisions .005, calibrated for vertical scale position.
|
|
G2001
|
Differential Pressure Gauge,Range 0-1.03 w.c.,minor divisions .02.
|
|
G2002
|
Differential Pressure Gauge,Range 0-2.03 w.c.,minor divisions .05.
|
|
G2003
|
Differential Pressure Gauge,Range 0-3.03 w.c.,minor divisions .10.
|
|
G2004
|
Differential Pressure Gauge,Range 0-4.03 w.c.,minor divisions .10.
|
|
G2005
|
Differential Pressure Gauge,Range 0-5.03 w.c.,minor divisions .10.
|
|
G2006
|
Differential Pressure Gauge,Range 0-6.03 w.c., minor divisions .20.
|
Additional Information:

Accurate Measurement for Demanding Applications
GEMTECH's Differential Pressure Gauge ensures high-precision monitoring of gas pressures within industrial systems. Its accuracy of 2% full scale makes it dependable in environments where precise pressure management is crucial, including clean room monitoring, filter condition checks, and system leak detection.
Versatile and Robust Construction
Constructed from quality metal alloys, the gauge withstands rigorous industrial settings like steel or cement plants. The durable plastic dial and alloy pointer enhance the product's lifespan, while the broad scale range allows adaptation across several process requirements.
Flexible Mounting and Connectivity Options
With its back-mount design and 1/8" NPT threaded connections (duplicate high and low pressure taps), installation is straightforward and accommodates various panel types. This flexibility supports integration into both new builds and retrofit projects.
FAQ's of GEMTECH Differential Pressure Gauge Range 0-5 Inches:
Q: How do I install the GEMTECH Differential Pressure Gauge in my system?
A: The gauge features a back-mounted design for easy panel installation. Use the 1/8" female NPT threads to connect both high and low pressure taps. The device provides one pair of taps on the side and one pair on the back, allowing for flexible piping arrangements to suit your system layout.
Q: What gases can I measure with this pressure gauge?
A: This gauge is designed specifically for measuring the pressure of various gases in industrial applications. It is commonly used for non-corrosive, clean gases in environments such as pharmaceutical, power, cement, steel, fertilizer, and textile plants.
Q: When should I consider recalibrating or servicing the gauge?
A: Periodic calibration is recommended to maintain the 2% full-scale accuracy, especially when used in environments with significant vibration, temperature variations, or critical process applications. Refer to your plant's maintenance schedule or calibrate annually to ensure consistent performance.
Q: Where is this differential pressure gauge typically used?
A: You'll find this gauge deployed in diverse sectors-including pharmaceuticals for cleanroom monitoring, power plants for filter checks, cement and steel plants for process control, as well as fertilizer and textile industries to monitor system pressures accurately.
Q: What is the measurement range and what scales are supported on the dial?
A: The gauge range is 0-5 inches, and the scale can be read in MM WC, CM, PAC, KPA, INCH, and PSI, providing versatility for different measurement standards and user preferences.
Q: How does this gauge benefit my process operations?
A: By delivering accurate pressure readings, this gauge supports optimized system performance, early leak detection, and timely maintenance, thereby reducing downtime and safeguarding sensitive processes in your facility.