GEMTECH Differential Pressure Gauge Range 0-10 MM
Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel,with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70 (21 (3% on -0,and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model |
Description |
| G2000-100MM |
Differential Pressure Gauge,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
Differential Pressure Gauge,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
Differential Pressure Gauge,Range 0-150 MM W.C. |
| G2000-15MM |
Differential Pressure Gauge,Range 0-15 MM W.C. |
| G2000-200MM |
Differential Pressure Gauge,Range 0-200 MM W.C. |
| G2000-250MM |
Differential Pressure Gauge,Range 0-250 MM W.C. |
| G2000-25MM |
Differential Pressure Gauge,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
Differential Pressure Gauge,Range 0-300 MM W.C. |
| G2000-50MM |
Differential Pressure Gauge,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
Differential Pressure Gauge,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
Differential Pressure Gauge,Range 0-80 MM W.C., Minor Divisions 2.0.
|
Additional Information:

Versatile Industrial ApplicationsGEMTECH Differential Pressure Gauge is engineered for industries requiring accurate differential pressure measurements, including pharmaceuticals, power generation, cement, steel, fertilizer, and textile sectors. Its robust build and reliable analog display make it ideal for critical monitoring and safety applications. With multiple thread and mounting options, it is adaptable for diverse installation scenarios, enhancing operational efficiency.
Precision Measurement and ReliabilityWith a measuring range from 0 to 10 mm and an accuracy specification of up to 2% of full scale, this gauge provides dependable and precise readings. The analog dial ensures clear visibility, and the metal alloy construction offers resilience for long-term use even in harsh environments. Back mounting allows for easy integration into systems, while the product's compliance with standard industrial processing ensures guaranteed performance.
FAQ's of GEMTECH Differential Pressure Gauge Range 0-10 MM:
Q: How does the GEMTECH Differential Pressure Gauge measure gas pressure differentials?
A: The gauge detects the difference in pressure between its high and low pressure taps, displaying the result on its analog dial. This makes it ideal for monitoring gas differential pressure in various systems.
Q: What industries benefit most from using this differential pressure gauge?
A: This gauge is well-suited for pharmaceutical, power plant, cement plant, steel plant, fertilizer, and textile industries due to its high accuracy and reliability in measuring low-range differential pressures.
Q: When should I choose the GEMTECH Differential Pressure Gauge over digital models?
A: Choose this analog gauge for robust environments where simple, immediate pressure readings are needed and electronic interference or maintenance concerns make digital options less suitable.
Q: Where can the GEMTECH Differential Pressure Gauge be installed?
A: It can be mounted using its back mount configuration and installed in systems with compatible 1/8" female NPT threads, offering side and back tap options for flexible setup.
Q: What is the benefit of the multiple scale ranges provided by this gauge?
A: Multiple scale readings (MM WC, CM, PAC, KPA, INCH, PSI) allow users to select the measurement units best suited for their specific application, simplifying integration and data interpretation.
Q: How accurate is this differential pressure gauge and under what conditions?
A: The device delivers up to 2% full-scale accuracy (with specified percentage changes for certain low-pressure ranges) when operated at or near 70F (21.1C), ensuring reliable data for sensitive processes.
Q: What is the process for purchasing or sourcing this gauge in India?
A: GEMTECH Differential Pressure Gauge is available through distributors, exporters, importers, manufacturers, suppliers, traders, and wholesalers across India, making it accessible for a variety of procurement needs.