About GEMTECH Differential Pressure Gauge In Light Industrial Area Bhilai Chhattisgarh

GEMTECH Differential Pressure Gauge In Light Industrial Area Bhilai Chhattisgarh
Series G2000, GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of filter, wind speed, furnace pressure, differential pressure of pore plate, the pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime, They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely. The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature - -21 140 6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa).
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70 21 3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure, Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges. Minimum is 0-60 Pa And Maximum is 0-21-KPa.
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
- FILTER BY
- Range - Pascals - Zero Center
| Model |
Description |
| G2300-100PA |
Differential Pressure Gage, Range 50-0-50 Pa,Minor Divisions 2.0,Calibrated For Vertical Scale Position. |
| G2300-120PA |
Differential Pressure Gage, Range 60-0-60 Pa,Minor Divisions 2.0. |
| G2300-250PA |
Differential Pressure Gage, Range 125-0-125 Pa,Minor Divisions 5.0. |
| G2300-500PA |
Differential Pressure Gage, Range 250-0-250 Pa,Minor Divisions 10.0. |
| G2300-60PA |
Differential Pressure Gage, Range 30-0-30 Pa,Minor Divisions 1.0,Calibrated For Vertical Scale Position. |
Additional Information:

Versatility Across Multiple Industries
Engineered to serve the demanding needs of power, cement, steel, fertilizer, pharmaceutical, and textile plants, the GEMTECH Differential Pressure Gauge ensures accurate gas pressure measurement in diverse industrial environments. Its robust build and precise readings make it the preferred choice for process monitoring and safety assurance.
Reliable and Flexible Performance
With its 4" plastic dial, alloy pointer, and durable metal alloy body, the gauge guarantees dependable results in light industrial settings. It features multiple pressure unit options and back-mounting capability, catering to various installation requirements. Its high accuracy and ease of connection simplify monitoring tasks for operators.
FAQ's of GEMTECH Differential Pressure Gauge In Light Industrial Area Bhilai Chhattisgarh:
Q: How does the GEMTECH Differential Pressure Gauge operate in light industrial environments?
A: The GEMTECH Differential Pressure Gauge measures the pressure difference between two points in a gas system, delivering reliable readings in light industrial settings such as pharmaceuticals, power plants, and manufacturing units. Its analog display and robust construction support consistent performance.
Q: What installation process is required for this differential pressure gauge?
A: Installation involves connecting the 1/8" female NPT high and low-pressure taps to your gas system-either side or back, based on the mounting configuration. The back mount design ensures seamless integration without occupying excessive space.
Q: When should regular calibration or maintenance be performed on this gauge?
A: It's recommended to inspect and calibrate the GEMTECH Differential Pressure Gauge at periodic intervals specified by your industry standards or when accuracy deviations are observed, ensuring sustained measurement reliability.
Q: Where can the GEMTECH Differential Pressure Gauge be deployed effectively?
A: This gauge is ideally suited for deployment in pharmaceutical processing, power plants, cement and steel facilities, fertilizer industries, and textile manufacturing, particularly where differential gas pressure monitoring is critical.
Q: What scale ranges and units does the GEMTECH Differential Pressure Gauge support?
A: The gauge supports multiple scale ranges, including MM WC, CM, PAC, KPA, INCH, and PSI, providing flexibility in pressure measurement according to operational requirements.
Q: How does the accuracy of the gauge benefit users in industrial applications?
A: With up to 2% full-scale accuracy, the gauge ensures precise differential pressure readings, enabling operators to make informed decisions for process efficiency and safety in critical environments.