About GEMTECH Differential Pressure Gauge Dealers Near Ram Manohar Lohia Hospital

GEMTECH Differential Pressure Gauge Dealers Near Ram Manohar Lohia Hospital
Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70 21 3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model |
Description |
| G2000-100MM |
Differential Pressure Gauge,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
Differential Pressure Gauge,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
Differential Pressure Gauge,Range 0-150 MM W.C. |
| G2000-15MM |
Differential Pressure Gauge,Range 0-15 MM W.C. |
| G2000-200MM |
Differential Pressure Gauge,Range 0-200 MM W.C. |
| G2000-250MM |
Differential Pressure Gauge,Range 0-250 MM W.C. |
| G2000-25MM |
Differential Pressure Gauge,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
Differential Pressure Gauge,Range 0-300 MM W.C. |
| G2000-50MM |
Differential Pressure Gauge,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
Differential Pressure Gauge,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
Differential Pressure Gauge,Range 0-80 MM W.C., Minor Divisions 2.0.
|
Additional Information:

Comprehensive Pressure Monitoring
GEMTECH Differential Pressure Gauges are engineered to provide accurate pressure readings for various gas applications. With scale options including MM WC, KPA, PSI, and more, users can select the ideal measurement unit for their needs. Their robust metal alloy body and stable analog mechanism ensure reliability even in demanding environments around Ram Manohar Lohia Hospital.
Effortless Installation and Versatile Application
Fitted with 1/8" female NPT dual high and low pressure connections, GEMTECH gauges support quick, secure installation. Their 4-inch diameter and clear analog face make readings easily visible, while the lightweight 550-gram design ensures manageability. Suitable for distributors, suppliers, exporters, and on-site technicians, they meet industry-standard processing requirements.
FAQ's of GEMTECH Differential Pressure Gauge Dealers Near Ram Manohar Lohia Hospital:
Q: How are GEMTECH Differential Pressure Gauges installed and connected?
A: GEMTECH Differential Pressure Gauges come with 1/8-inch female NPT taps for both high and low pressure sides, available as pairs on the side and back. This design allows for flexible installation on different systems. Simply choose the desired mounting orientation, connect the appropriate gas lines, and ensure all fittings are secure for optimal performance.
Q: What pressure ranges and units can the GEMTECH gauge measure?
A: The gauge offers a wide variety of scale ranges, including MM WC, CM, PAC, KPA, INCH, and PSI. These options enable users to select the most relevant unit for their application, making the gauge suitable for gas pressure measurement in diverse industrial settings.
Q: When should the GEMTECH Differential Pressure Gauge be used?
A: This gauge is ideal for continuous or periodic monitoring of gas pressure differences in pipelines, HVAC systems, and process equipment. Use it during system installation, commissioning, or routine maintenance whenever accurate pressure readings are crucial for safety and efficiency.
Q: Where can I purchase the GEMTECH Differential Pressure Gauge near Ram Manohar Lohia Hospital?
A: The GEMTECH Differential Pressure Gauge is available through verified dealers, distributors, and suppliers near Ram Manohar Lohia Hospital, India. Buyers may contact local industrial equipment providers or reputable online distributors specializing in pressure instruments.
Q: What is the process for reading the GEMTECH gauge's analog display?
A: The gauge is designed with a 4-inch (101.6 MM) diameter plastic dial featuring clear white or black backgrounds for readability. The alloy pointer moves in response to pressure changes, allowing users to quickly and precisely read values on the selected scale. Simply observe the pointer's position relative to the marked units.
Q: What benefits do GEMTECH Differential Pressure Gauges offer?
A: Key advantages include robust metal alloy construction for durability, high measurement accuracy (2%-4% of FS depending on model and range), flexible scale and mounting options, and a clear analog interface. These features collectively ensure reliable performance and contribute to safer, more efficient operation of gas systems.