About G2080 GEMTECH Differential Pressure Gauge Range 0-80 Inch WC

G2080 GEMTECH Differential Pressure Gauge Range 0-80 Inch WC
Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70???(21??????(3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model |
Description |
| G2000-100MM |
DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
DPG,Range 0-150 MM W.C. |
| G2000-15MM |
DPG,Range 0-15 MM W.C. |
| G2000-200MM |
DPG,Range 0-200 MM W.C. |
| G2000-250MM |
DPG,Range 0-250 MM W.C. |
| G2000-25MM |
DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
DPG,Range 0-300 MM W.C. |
| G2000-50MM |
DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
DPG,Range 0-80 MM W.C., Minor Divisions 2.0. |
Additional Information:
Wide Application in Industrial Settings
This pressure gauge is crafted for use in demanding environments, particularly within pharmaceutical industries where precise gas measurement is critical. Its broad compatibility with multiple pressure units and wide scale range ensures accurate monitoring and control of processes, supporting operational safety and regulatory compliance.
Robust Build and Versatile Mounting
Constructed from high-grade metal alloy and featuring a durable plastic dial face, the G2080 GEMTECH pressure gauge balances strength with reliability. The dual high and low pressure taps and back mount type offer installation flexibility, making it suitable for various system designs and configurations.
FAQ's of G2080 GEMTECH Differential Pressure Gauge Range 0-80 Inch WC:
Q: How do I install the G2080 GEMTECH Differential Pressure Gauge?
A: The gauge features a back mount and comes with both side and back high/low pressure taps, each using a 1/8" female NPT thread. Simply select the preferred tap position based on your system design and securely connect it using standard fittings.
Q: What environments are suitable for using this pressure gauge?
A: This gauge is tailored for environments requiring accurate differential gas pressure measurement, such as pharmaceutical industries. It can also be used in other industrial settings where gas monitoring is important.
Q: When should I use this gauge instead of other models?
A: Use the G2080 GEMTECH when you require precise differential pressure readings across a wide scale range (0-80 Inch WC) with a high level of accuracy (2% FS) and multi-unit display capability. Its robust design is ideal for scenarios demanding durability and reliability.
Q: Where can I purchase the G2080 GEMTECH Differential Pressure Gauge?
A: This product is distributed, exported, imported, manufactured, supplied, and traded by various vendors in India. Contact authorized GEMTECH distributors or visit industry suppliers for purchase.
Q: What is the main process for measuring pressure using this device?
A: The gauge utilizes high and low pressure taps to detect differential pressure between two points, with real-time analog display on its 4-inch dial face. The scale offers readings in multiple units, including MM WC and PSI.
Q: What is the benefit of the dual high and low pressure taps?
A: Having two pairs of high and low pressure taps (side and back) offers added installation flexibility, allowing you to select the most convenient configuration for your system's layout, enhancing ease of maintenance and accuracy of readings.
Q: How accurate is the G2080 GEMTECH Differential Pressure Gauge?
A: This model offers 2% of full scale accuracy (1% for HA models), with some ranges varying between 3% and 4% depending on low-pressure configurations. This ensures dependable performance in critical applications.