Dwyer USA Magnehelic Gauges 0 To 150 MM WC
Dwyer USA Magnehelic Gauges 0 To 150 MM WC

Dwyer USA Magnehelic Gauges 0 To 150 MM WC

Dwyer USA Magnehelic Gauges 0 To 150 MM WC Specification

  • Outer Size
  • 110 mm (approx.)
  • Bourdon Tube
  • Not Applicable (Diaphragm type)
  • Thread
  • 1/8 NPT Female
  • Display
  • Analog Gauge
  • Seal Material
  • Silicone Rubber
  • Grade
  • Industrial Grade
  • Sensor Type
  • Diaphragm Sensing Element
  • Material
  • Die Cast Aluminum Case
  • Dial Material
  • Aluminum, white background
  • Pointer Material
  • Black-finished Aluminum
  • Processing Type
  • Precision Machined
  • Diameter
  • 4 inch (100mm nominal)
  • Glass Size
  • 100 mm approx.
  • Mount Type
  • Surface / Flush Mounting
  • Scale Range
  • 0 to 150 mm WC
  • Accuracy
  • 2% of full scale
  • Finishing
  • Corrosion-resistant enamel finish
  • Measure Pressure Of
  • Low Air or Non-Corrosive Gas
  • Accessories
  • Two compression fittings, three mounting adapters, four screws
  • Ingress Protection
  • IP52
  • Model
  • Dwyer Magnehelic Series 2000
  • Operating Temperature
  • -7C to 60C
  • Overpressure Protection
  • Rupture-proof up to twice maximum pressure rating
  • Zero Adjustment
  • External adjustment screw
  • Weight
  • Approximately 400 grams
  • Application
  • HVAC systems, Cleanrooms, Filter monitoring, Duct Static Pressure
  • Window Material
  • Clear Acrylic
  • Connection Location
  • Side and back
 

Dwyer USA Magnehelic Gauges 0 To 150 MM WC Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, North America, Eastern Europe, Middle East, Western Europe, Africa, Central America, South America, Asia
  • Main Domestic Market
  • All India
 

About Dwyer USA Magnehelic Gauges 0 To 150 MM WC

Dwyer USA Magnehelic Gauges 0 To 150 MM WC

INCLUDES

Two 1/8" NPT plugs, two 1/8" rubber tubing adapters, and three mounting adapters with screws

MORE ABOUT THIS ITEM

The Magnahelic guage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems, and pressures in fluid amplifier or fluidic systems. The gauge's motion is damped with high-viscosity silicone fluid. The zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness. Rugged design resists shock, vibration, and overpressure.

The helix is precision-made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the maganetic field to move the pointer across the scale. The samarium cobalt magnet is mounted at one end of the range spring and rotates the helix without mechanical linkages.

Specifications & Description 

 

 Accuracy±2% full-scale
 Dial Size (in)
 Dial Size (mm)102 
Min Pressure (in WC)
 Max Pressure (in WC)10 
Wetted Materials Aluminum
 Case Aluminum
 Lens Materialacrylic
 Process Connection1/8" NPT
 Unit Of Measurement " WC
 Displayanalog dial
 Media Compatibility Gases and liquids compatible with wetted materials
 Resolution 0.20
 Description Magnehelic Differential Pressure Gauge, Type , 0 to 150 MM WC
 


Precision for Demanding Environments

Purpose-built for industrial applications, the Dwyer Magnehelic Gauge offers outstanding reliability in cleanrooms, HVAC systems, and filter monitoring. Its diaphragm sensing element delivers superior accuracy and response for measurements involving low air or non-corrosive gases. The corrosion-resistant enamel finish ensures longevity even in challenging settings.


Versatile Mounting and User-Friendly Features

This gauge supports both surface and flush mounting, making installation on panels or ducts straightforward. The external zero adjustment screw simplifies calibration, while its clear analog display with a 100mm dial facilitates easy reading. Side and back connection options further enhance adaptability on site.

FAQs of Dwyer USA Magnehelic Gauges 0 To 150 MM WC:


Q: How do I install the Dwyer Magnehelic Gauge in my HVAC system?

A: Installation can be performed via surface or flush mounting using the supplied screws and adapters. The gauges side and back connection ports (1/8 NPT female) provide flexibility for panel or duct mounting, ensuring optimal placement for accurate low-pressure measurements in your HVAC application.

Q: What pressure ranges can the Magnehelic Gauge measure, and what gases is it compatible with?

A: This model measures differential pressures from 0 to 150 mm WC and is engineered for low air or non-corrosive gas applications. It is suitable for cleanrooms, duct static pressure measurement, and filter monitoring without risk of chemical incompatibility with sensitive sensor components.

Q: When is it necessary to zero adjust the gauge and how is it done?

A: If the pointer does not indicate zero when no pressure is applied, use the external adjustment screw to reset it. This ensures the accuracy of readings and should be checked before initial use or after extended operation, particularly in environments with frequent pressure fluctuations.

Q: Where can the Magnehelic Gauge be mounted for effective monitoring?

A: It can be surface or flush mounted on HVAC panels, ductwork, or cleanroom walls. Its compact 100mm diameter and provided mounting accessories make installation on most surfaces straightforward, allowing for optimal visibility and accessibility in various industrial settings.

Q: What protections does the gauge have against overpressure and environmental conditions?

A: The Magnehelic Gauge is rupture-proof up to twice its maximum rated pressure and features IP52 ingress protection, safeguarding it from dust and limited water ingress. The die-cast aluminum case and corrosion-resistant enamel finish further enhance its durability and reliability in demanding environments.

Q: How does using this gauge benefit filter monitoring processes?

A: By providing precise pressure differential readings, the gauge enables early detection of filter clogging or reduced airflow. This helps in timely maintenance and replacement, ensuring optimal system efficiency and preventing costly downtime in industrial and cleanroom environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Sensocon - Dwyer S2000 Differential Pressure Gauge Category

Dwyer 2203 Magnehelic Differential Pressure Gauge 0-3 PSI

Dwyer 2203 Magnehelic Differential Pressure Gauge 0-3 PSI

Minimum Order Quantity : 12 Pieces

Sensor Type : Differential Pressure Diaphragm

Measure Pressure Of : Other, Air and noncorrosive gases

Finishing : Other, Black matte finish with clear acrylic cover

Scale Range : 03 PSI

Accuracy : 2% of full scale

Dwyer USA Model 2025 Magnehelic Gage Range 0-25 Inch WC

Dwyer USA Model 2025 Magnehelic Gage Range 0-25 Inch WC

Minimum Order Quantity : 12 Pieces

Sensor Type : Mechanical (Diaphragm)

Measure Pressure Of : Other, Low differential air and noncorrosive gases

Finishing : Other, Black finish bezel with clear acrylic cover

Scale Range : 025 Inch WC (Water Column)

Accuracy : 2% of Full Scale

Dwyer 2000-0AV Magnehelic Differential Pressure Gauge

Dwyer 2000-0AV Magnehelic Differential Pressure Gauge

Minimum Order Quantity : 12 Pieces

Sensor Type : Diaphragm

Measure Pressure Of : Other, Air and noncorrosive gases

Finishing : Other, Black anodized aluminum casing

Scale Range : 00.2 inch w.c.

Accuracy : 2% of full scale

Dwyer 2000-750PA Magnehelic Differential Pressure Gauge

Dwyer 2000-750PA Magnehelic Differential Pressure Gauge

Minimum Order Quantity : 12 Pieces

Sensor Type : Diaphragm

Measure Pressure Of : Other, Air and Noncorrosive Gases

Finishing : Other, Textured black finish housing

Scale Range : 0750 Pa

Accuracy : 2% of full scale



Back to top