About DWYER MSX-W11-IN Differential Pressure Transmitter

DWYER MSX-W11-IN Differential Pressure Transmitter
- MSX-W11-IN | Dwyer Instruments | Pressure
- DIFF PRESS XMTR, UNIVERSAL MOUNT, UNI CURRENT/VOLT OUT, UNI-DIRECTIONAL, RANGE 0.1, 0.25, 0.5, 1
- Brand:Dwyer Instruments
PRODUCTS SPECIFICATIONS :
- Approvals : CE
- Direction : Uni-Directional
- Housing Rating : NEMA 4X
- Media Compatibility : Liquid/Gas
- Range : 1 in WC
- Type : Multi
- Supply Voltage (Nominal): 24 VDC
PRODUCTS SERIES SPECIFICATIONS :
- Service: Air and non-combustible, compatible gases
- Accuracy: 1% FSO
- Stability: 1% FSO/year
- Temperature Limits: -4 to 158F (-20 to 70C)
- Pressure Limits: Ranges 0 and 1: 3.6 psi max operation, 6 psi burst; Ranges 2 and 3: 6 psi max operation, 6 psi burst
- Power Requirement: 10-36 VDC (2-wire), 17-36 VDC or isolated 21.6-33 VAC (3-wire)
- Response Time: 4-20 mA (2-wire); 0-10 V or 0-5 V selectable (3-wire)
- Zero and Span Adjustments: Digital push-button
- Loop Resistance: Current output: 0-1250 O max; Voltage output: min. load resistance 1 k O
- Current Consumption: 21 mA max continuous
- Electrical Connections: 4-wire removable European style terminal block for 16 to 26 AWG
- Electrical Entry: 1/2" NPS thread
- Display (optional): 4 digit LCD
- Process Connections: 1/8", 3/16", 1/4", 5 mm, and 6 mm ID flexible tubing
- Enclosure Rating: NEMA 4X (IP66), UL 2043 (Plenum), UL94 V-0
- Mounting Orientation: Pressure sensor measurement unaffected by orientation
- Weight: 8.0 oz (230 g)
- Approvals: CE
PRODUCTS SERIES FEATURES :
- Rotatable 180 Degree Display For Ease Of Reading
- Optional Toolless Terminal Block Allows For Quick And Easy Wiring
- UL94 V-0 and Plenum Rating That Add Safety To a Variety Of Applications
MORE INFORMATION & RELATED DOCUMENTS :
The Series MSX Magnesense Differential Pressure Transmitter combines the stability and versatility of the original Series MS2 Magnesense II Transmitter for Use in Building control applications. The MSX Simplifies the Ordering Process to Deliver The Desired Configuration, which reduces product setup time. Pressure Ranges are available in Pa, mm w.c., and in w.c. All Pressure Ranges can be configured in unidirectional or bidirectional modes, providing a total of 32 ranges. The MSX Transmitter can provide a linear pressure output or a linear velocity output with the square root extraction from the transmitter. Additional parameters have been included to expand the square root capability for calculating flow. Dual voltage and milliamp output signals can be used to provide both control and equipment output signal verification.
- ENVIRO TECH Description : DIFF PRESS XMTR, UNIVERSAL MOUNT, UNI CURRENT/VOLT OUT, UNI-DIRECTIONAL, RANGE 0.1, 0.25, 0.5, 1
- Manufacturer : Dwyer Instruments
Additional Information:
- Item Code: DWYER-MSX-W11-IN-Differential-Pressure-Transmitter
- www.envirotechdelhi.com
- www.envirotechindia.co.in
- www.envirotechdelhi.in

Precision Measurement for Industrial GasesThe DWYER MSX-W11-IN Differential Pressure Transmitter is crafted to deliver precise and consistent pressure readings for gases across multiple scale ranges. Its robust construction and dependable performance make it ideal for continuous monitoring in critical industrial processes.
Versatile Industrial ApplicationsThis transmitter is tailored for use in power plants, cement factories, steel plants, fertilizer manufacturing, and textile production. Its compatibility with a range of applications ensures reliable integration into new or existing systems for enhanced operational control.
FAQ's of DWYER MSX-W11-IN Differential Pressure Transmitter:
Q: How is the DWYER MSX-W11-IN Differential Pressure Transmitter installed?
A: The transmitter is designed for surface mounting, allowing for quick and secure installation on panels or flat surfaces within your facility. Ensure the mounting location provides easy access to the pressure lines and is protected from harsh environmental factors.
Q: What types of gases can be monitored using this pressure transmitter?
A: This model is primarily intended for measuring the differential pressure of non-corrosive gases used in process industries, making it suitable for environments like power, cement, steel, fertilizer, and textile plants.
Q: When should this transmitter be calibrated or maintained?
A: Regular calibration and maintenance should be conducted according to your plant's standard operating procedures, typically every 6-12 months, to maintain the specified 1% FSO accuracy.
Q: Where is the best location to use the DWYER MSX-W11-IN within a plant?
A: Optimal placement is at points in the gas system where accurate differential pressure measurement is crucial for process control, such as filter monitoring, duct pressure checks, or airflow management sections.
Q: What are the key benefits of using this differential pressure transmitter?
A: Key advantages include precise measurement of low-pressure differentials, lightweight construction (250 grams), compatibility with several process industries, and resilient plastic materials ensuring long-term durability.
Q: How does the absence of a digital display affect data monitoring?
A: While the unit lacks a built-in display, it is designed to interface with external monitoring or control systems, enabling remote readouts and integration with your plant's existing automation infrastructure.
Q: What is the process for exporting or importing this transmitter in India?
A: Distribution is managed through certified exporters, importers, and suppliers across India. Coordinate with authorized dealers or manufacturers to ensure compliance with local regulatory standards and proper documentation during shipping and installation.