About 0-125 Pa. Dwyer A3000-125PA Photohelic Pressure Switch Gauge Range
Dwyer A3000-125PA Photohelic Pressure Switch Gauge Range 0-125 Pa.
Dwyer A3000-125PA Photohelic Pressure Switch/Gauge (0-125 Pa)
Model: A3000-125PA
Bezel and Front Cover (With Set Point Knobs And Zero Adjustment Screw) Removed To Expose Photohelic Switch/Gage Set Point Mechanism. Gage Pointer And Light Shutter Are Mounted On Helix And Balancing Counter Weight.
Dwyer A3000-125PA Offers
Features
- Measure 4 to 20 mA signals without "breaking the loop"
- Measure mA signals for PLC and control system analog I/O
- Dual backlit display with both mA measurement and percent of 4 to 20 mA span
- Measurement Spotlight illuminates hard to see wires in dark enclosures
- Detachable clamp with extension cable for measurements in tight locations
- Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
- Automatically change the 4 to 20 mA output for remote testing
- Power saving features, auto-off, backlight timeout extend battery life
- Hold function captures and displays changing measurements
- Applications
- Air Conditioner Systems
- Clean Rooms
- Fume Exhaust Systems
Specifications
GAGE SPECIFICATIONS
Service:Air and Non-Combustible, Compatible Gases.
Wetted Materials:Consult Factory.
Accuracy:2% of FS at 70F (21.1C). 3% on -0 and 4% on -00 models.
Pressure Limits:-20" Hg. to 25 psig (-0.677 to 1.72 bar). MP option; 35 psig (2.41 bar), HP option; 80 psig (5.52 bar).
Temperature Limits:20 to 120F. (-6.67 to 48.9C). -20 to 120F (-28 to 48.9C) with low temperature option.
Process Connections:1/8" female NPT.
Size:4" (101.6 mm) dial face, 5" (127 mm) O.D. x 8-1/4" (209.55 mm).
Weight:4 lb (1.81 kg).
SWITCH SPECIFICATIONS
Switch Type:Each setpoint has 2 Form C relays (DPDT).
Repeatability:1% of FS.
Electrical Rating:10 A @ 28 VDC, 10 A @ 120, 240 VAC.
Electrical Connections:Screw terminals. Use 167F (75C) copper conductors only.
Power Requirements:120 VAC, 50/60 Hz; 240 VAC & 24 VAC power optional.
Mounting Orientation:Diaphragm in vertical position. Consult factory for other position orientations.
Set Point Adjustment:Adjustable knobs on face.
Agency Approvals:CE, CSA, UL.
Reliable Pressure Monitoring for Critical EnvironmentsWith its specialized capsule diaphragm sensor and dual SPDT relay outputs, the A3000-125PA excels in monitoring differential air pressure, crucial for tasks like cleanroom and HVAC control. The analog dial allows for clear visual pressure assessment, while rapid response switching directly helps trigger alarms or automated actions when setpoints are reached.
Engineered for Durability and Easy IntegrationConstructed from die-cast aluminum with a satin case and a polycarbonate lens, the A3000-125PA stands up well to demanding industrial environments. The included mounting hardware eases installation, whether you opt for flush or surface mounting. Standard 1/8" NPT female connections make it compatible with commonly used pressure lines in air and non-corrosive gas systems.
FAQ's of 0-125 Pa. Dwyer A3000-125PA Photohelic Pressure Switch Gauge Range:
Q: How is the Dwyer A3000-125PA typically installed and connected?
A: The A3000-125PA can be mounted either flush or on a surface panel using the included mounting hardware. Pressure connections are achieved via two 1/8" NPT female ports for high and low differential readings, making installation straightforward in standard HVAC and process control setups.
Q: What types of applications benefit from using this pressure switch gauge?
A: This instrument is ideal for HVAC systems, cleanrooms, filter monitoring, and any differential air pressure control applications dealing with low air or non-corrosive gases, ensuring proper system operation and safety through real-time monitoring and relay actuation.
Q: When should I consider using the dual SPDT snap-action switches?
A: Dual SPDT switches are useful when you need to trigger separate alarm points or control circuits. For instance, you might want automated ventilation to activate at a low-pressure point and an alarm to sound at a higher threshold, ensuring comprehensive system responses.
Q: What is the process for calibrating or maintaining the A3000-125PA?
A: Each unit is factory calibrated, so on-site calibration is typically unnecessary. Maintenance mainly involves ensuring the pressure ports and diaphragm remain free from particulates and that electrical connections are secure. Refer to the included instruction manual for details.
Q: Where should this gauge not be used due to its ingress protection rating?
A: The A3000-125PA is not rated for outdoor use or immersion in liquids. It's designed for indoor environments where it won't be subject to weather, water splashes, or high humidity that could affect its performance.
Q: What are the benefits of the analog display and switch output combination?
A: The analog display provides a real-time, easy-to-read indication of pressure levels, while the switch outputs allow direct integration into control systems for automated responses, combining monitoring and control in a single device.