Dual Scale Diff.Test Gauge, 0-3.0"H2O/0-750Pa
Select the Magnehelic gage for high accuracy--guaranteed within 2% of full scale--and for the wide choice of 81 models available to suit your needs precisely. Using Dwyer's simple, frictionless Magnehelic gage movement, it quickly indicates low air or non-corrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It's inexpensive, too. The Magnehelic gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment.
Product Highlights
- Bezel provides flange for flush mounting in panel.
- Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale.
- Precision litho-printed scale is accurate and easy to read.
- Red tipped pointer of heat treated aluminum tubing is easy to see. It is rigidly mounted on the helix shaft.
- Pointer stops of molded rubber prevent pointer over-travel without damage.
- "Wishbone" assembly provides mounting for helix, helix bearings and pointer shaft.
- Jeweled bearings are shock-resistant mounted; provide virtually friction-free motion for helix. Motion damped with high viscosity silicone fluid.
- Zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness.
- Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the magnetic field to move the pointer across the scale.
- Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reacts to pressure on diaphragm. Live length adjustable for calibration.
- Silicone rubber diaphragm with integrally molded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures.
- Die cast aluminum case is precision made and iridite-dipped to withstand 168 hour salt spray corrosion test.
- Exterior finished in baked dark gray hammerloid. One case size is used for all standard pressure options, and for both surface and flush mounting.
Overpressure Protection
Blowout plug is comprised of a rubber plug on the rear which functions as a relief valve by unseating and venting the gage interior when over pressure reaches approximately 25 PSIg (1.7 bar). To provide a free path for pressure relief, there are four spacer pads which maintain 0.023" clearance when gage is surface mounted. Do not obstruct the gap created by these pads. The blowout plug is not used on models above 180" of water pressure, medium or high pressure models, or on gages which require an elastomer other than silicone for the diaphragm. The blowout plug should not be used as a system overpressure control. High supply pressures may still cause the gage to fail due to over pressurization, resulting in property damage or serious injury. Good engineering practices should be utilized to prevent your system from exceeding the ratings or any component.
O-ring seal for cover assures pressure integrity of case. Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkages.
- Range 0-3.0 in H2O
- 0-750 Pa
Versatile Industrial ApplicationsThe Dwyer 2003D Magnehelic Gauge is designed to meet the demanding needs of various industries including power plants, cement manufacturing, steel production, fertilizer factories, and textile industries. Its reliable performance ensures accurate monitoring under diverse operating conditions.
Precision Engineering for Reliable ResultsBoasting an accuracy of 1% FSO and a broad range of pressure scales, the Magnehelic 2003D instrument provides precise differential pressure measurements. Its robust 4-inch dial face enhances readability, making it suitable for critical monitoring tasks in industrial processes.
Simple Installation and Durable DesignWeighing just 550 grams and equipped with an NPT 1/8-inch thread, the gauge is easy to install on-site. Its compact, white/black construction is optimized for long-term durability, ensuring dependable service in challenging environments across Indian industries.
FAQ's of Dwyer 2003D Magnehelic Differential Pressure Gauge:
Q: How do I install the Dwyer 2003D Magnehelic Differential Pressure Gauge?
A: To install the Dwyer 2003D Magnehelic Gauge, use the NPT 1/8-inch threaded connection to securely mount it at the required location. Ensure that the gauge is positioned upright to maintain the specified accuracy and follow any instructions provided with the product for optimal performance.
Q: What industries commonly use the Dwyer 2003D Magnehelic Gauge?
A: The Dwyer 2003D Magnehelic Differential Pressure Gauge is widely used in power plants, cement production, steel manufacturing, fertilizer plants, and textile industries. Its robust design and versatility make it suitable for a variety of demanding industrial applications.
Q: When should this pressure gauge be used over digital alternatives?
A: This mechanical gauge is ideal for applications that require reliability without power sources, resistance to electrical interference, or continuous visual monitoring. It is especially favored in environments where digital displays are not practical or necessary.
Q: Where can I purchase the Dwyer 2003D Magnehelic Gauge in India?
A: You can obtain the Magnehelic 2003D from authorized distributors, exporters, importers, manufacturers, suppliers, traders, and wholesalers throughout India. Check with reputable industrial equipment providers for availability and support.
Q: What process media are compatible with the Dwyer 2003D Magnehelic Gauge?
A: The gauge is designed for air and compatible non-corrosive gases, commonly used in ventilation, filtration monitoring, and process control to ensure equipment and safety standards are maintained.
Q: How does the Dwyer 2003D add value to industrial operations?
A: By providing highly accurate pressure differential readings (1% FSO), this gauge enables process optimization, improved safety, and efficient system monitoring, reducing downtime and aiding regulatory compliance across several industries.