double - edge - fold - fills Specification

  • Material
  • PVC (Polyvinyl Chloride)
  • Application
  • Cooling Towers, Air Conditioning, Power Plants, Industrial Water Cooling
  • Air Flow
  • High, depends on cooling tower capacity
  • Condition
  • New
  • Type
  • Double Edge Fold Fills
  • Dimension (L*W*H)
  • 600mm x 300mm x 150mm (customizable)
  • Cooling Type
  • Cross-flow and Counter-flow Cooling Towers
  • Water Flowing Rate
  • High-efficiency distribution
  • Noise Control
  • Effective splash attenuation
  • Flute Spacing
  • Customizable as per cooling requirement
  • Installation
  • Easy to install with mechanical support
  • Temperature Resistance
  • Withstands up to 60°C
  • Thickness
  • 0.28mm to 0.35mm (as per requirement)
  • Feature
  • High efficiency, anti-fouling, UV resistant
  • Color
  • Blue / Black
  • Flute Height
  • 19mm or as per design
  • Service Life
  • Above 10 years under standard conditions
  • Packing
  • Bulk or as per client request
  • Shape
  • Double Edge Fold / Chevron Profile
 
 

About double - edge - fold - fills

Double Edge Fold Fills

To gain strong foothold in this industry, we are devoted toward offering a wide gamut of Double Edge Fold Fills. Only high quality raw material is used while manufacturing the offered range, for increased compliance with international standards of quality. The offered range is highly appreciated among clients for its excellent and sturdy design. Apart from this, our range is offered in various sizes and can be customized, as per precise needs of our clients at highly competitive prices. 

Features:

  • Sturdiness
  • Excellent quality
  • Durability


Other Information

  • Pay Mode Terms: T/T (Bank Transfer)


Precision Engineered for Superior Cooling

Our Double Edge Fold Fills, crafted in a Chevron Profile, deliver remarkable cooling performance across a range of applications, including cooling towers and industrial water systems. Each fill is designed to ensure optimal airflow and water distribution, making them a reliable solution for demanding environments.


Flexible and User-Friendly Installation

Designed for easy integration, these double-edge folds can be installed with basic mechanical supports, minimizing downtime. Whether youre upgrading an existing system or setting up a new installation, their customizable dimensions and packing options make them a versatile choice for projects of varying scales.


Durable and Efficient in All Conditions

Engineered from high-grade PVC or similar materials, these fills resist fouling and ultraviolet radiation, maintaining efficiency even under challenging conditions. They can reliably operate at temperatures up to 60C and provide a service life of over a decade when maintained under standard conditions.

FAQs of double - edge - fold - fills:


Q: How do Double Edge Fold Fills enhance the efficiency of cooling towers?

A: Double Edge Fold Fills utilize a Chevron Profile and customizable flute spacing, which promote high airflow and superior water distribution. This design ensures effective heat exchange, significantly improving cooling tower performance and energy efficiency.

Q: What installation process is recommended for these fills?

A: Installation is straightforward and requires only mechanical support to secure the fills in place. Their customizable dimensions allow them to fit existing or new cooling towers with ease, ensuring minimal disruption during setup.

Q: Where can these Double Edge Fold Fills be used most effectively?

A: These fills are ideal for use in cooling towers found in industrial water cooling, air conditioning systems, and power plants. Their high efficiency and robust construction suit both cross-flow and counter-flow cooling tower designs.

Q: What are the main benefits of choosing these fills for industrial cooling applications?

A: Key benefits include high thermal efficiency, anti-fouling properties, UV resistance, noise control due to splash attenuation, and a long service life of over 10 years. Their design also allows for greater customization according to cooling requirements.

Q: How customizable are the dimensions and flute characteristics of these fills?

A: Both the overall dimensions and the flute characteristics (height and spacing) can be modified to match specific design and cooling requirements, ensuring optimal system compatibility and efficiency.

Q: What materials are used in the construction of these fills, and how does this impact their durability?

A: The fills are manufactured from PVC or other durable materials, providing resistance to chemicals, fouling, and UV degradation. This ensures consistent performance and longevity, even in demanding industrial environments.

Tell us about your requirement
product

Price:  

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in PVC Cooling Tower Accessories Manufacturer India Category

honeycomb- pvc -fills

honeycomb- pvc -fills

Material : Other , Rigid Polyvinyl Chloride (PVC)

Cooling Type : Evaporative Cooling

Application : Cooling Towers, Industrial Cooling Systems, HVAC

Type : Honeycomb PVC Fill

Dimension (L*W*H) : 600mm x 300mm x 150mm (customizable)

Condition : New

pvc- fills

pvc- fills

Material : Other , Rigid PVC

Cooling Type : Evaporative

Application : Cooling Towers, Industrial Water Cooling

Type : PVC Fills / Fill Media

Dimension (L*W*H) : 1200 mm x 600 mm x 150 mm (Common size, customizable)

Condition : New

sigma-type- pvc-fill

sigma-type- pvc-fill

Material : Other , PVC (Polyvinyl Chloride)

Cooling Type : Water Cooling

Application : Cooling Tower / Industrial Water Cooling

Type : Sigma Type PVC Fill

Dimension (L*W*H) : 600 mm x 300 mm x 150 mm, or customized

Condition : New

cooling- tower-pvc-fill

cooling- tower-pvc-fill

Material : Other , PVC (Polyvinyl Chloride)

Cooling Type : Wet Cooling

Application : Cooling Towers, Water Cooling Systems

Type : Honeycomb PVC Fill

Dimension (L*W*H) : 600 mm x 300 mm x 150 mm (Typical)

Condition : New



Back to top