DIDW Centrifugal Fan 250 MM X 228 MM
DIDW Centrifugal Fan 250 MM X 228 MM

DIDW Centrifugal Fan 250 MM X 228 MM

MOQ : 12 Pieces

DIDW Centrifugal Fan 250 MM X 228 MM Specification

  • Efficiency
  • Up to 85%
  • Automation Grade
  • Manual / Semi-Automatic
  • Orientation
  • Horizontal
  • Usage & Applications
  • Industrial ventilation, HVAC systems, dust collection
  • Temperature
  • Ambient 60C Max
  • Power Source
  • Electric
  • Air Flow
  • 3600 m/hr
  • Measurement
  • Standard
  • Instruments Type
  • Fan / Blower
  • Product Type
  • Double Inlet Double Width (DIDW) Centrifugal Fan
  • Material
  • Mild Steel
  • Cooling System
  • Air Cooled
  • Noise Level
  • 72 dB
  • Processing Time
  • Continuous
  • Capacity
  • 3600 CFM
  • Voltage
  • 415 V
  • Weight
  • Approx. 48 kg
  • Dimension (L*W*H)
  • 250 mm x 228 mm (Impeller Size)
  • Surface
  • Powder coated
  • Inlet Size
  • 250 mm
  • Drive Type
  • Belt Driven
  • Mounting Type
  • Base Mounted
  • Impeller Type
  • Backward Curved
  • Number of Blades
  • 10
  • Insulation Class
  • Class F
  • Bearings
  • Heavy Duty Ball Bearing
  • Motor Power
  • 3 HP
  • Outlet Size
  • 228 mm
  • Speed
  • 1440 RPM
  • Casing Type
  • Volute
  • Static Pressure
  • 60 mmWC
  • Protective Features
  • ISI Marked Motor, Overload Protection
 

DIDW Centrifugal Fan 250 MM X 228 MM Trade Information

  • Minimum Order Quantity
  • 12 Pieces
  • Payment Terms
  • Paypal, Cash Against Delivery (CAD), Telegraphic Transfer (T/T), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, North America, Eastern Europe, Middle East, Africa, Central America, South America, Western Europe, Asia
  • Main Domestic Market
  • All India
 

About DIDW Centrifugal Fan 250 MM X 228 MM

DIDW Centrifugal Fan 250 MM X 228 MM

DIDW CENTRIFUGAL BLOWER  

 SL.NO CATALOGUE NO  MILLIMETERS  INCHES  BORE SIZE  MATERIAL 
    OD X HT X ID  OD X HT   MM & INCH
39 ETIP 10 90  250 X 228X 210 10 X 9 12.70 (1/2) & 15 MM  AL. / GI.  


Engineered for Industrial Demand

Designed for continuous use, the DIDW Centrifugal Fan delivers optimal air volume (3600 m/hr) at a high efficiency of up to 85%. With a backward curved, 10-blade impeller and robust mild steel casing, it efficiently handles ventilation, dust extraction, and HVAC duties in industrial and commercial environments throughout India.


Reliable Protection & Longevity

Equipped with an ISI Marked, Class F insulated motor and heavy-duty ball bearings, this fan offers solid overload protection, noise reduction, and minimal maintenance. Its air-cooled system and powder-coated finish enhance rust resistance and operational life, providing dependable performance through continuous operation.

FAQs of DIDW Centrifugal Fan 250 MM X 228 MM:


Q: How does the backward curved impeller benefit this centrifugal fans performance?

A: The backward curved impeller design improves aerodynamic efficiency, reduces energy consumption, and helps manage high static pressure loads (up to 60 mmWC), ensuring reliable air delivery and quiet operation.

Q: What applications is the DIDW Centrifugal Fan best suited for?

A: This fan is ideal for industrial ventilation, HVAC systems, and dust collection. Its high capacity, durable structure, and continuous processing capability make it suitable for manufacturing plants, commercial buildings, and workshops.

Q: When should I perform maintenance on this fan?

A: Routine maintenance is recommended every 36 months, focusing on checking the ball bearings, belt tension, and cleaning to sustain optimal performance, especially in dusty or high-use environments.

Q: Where can this centrifugal fan be installed?

A: Due to its base-mounted, horizontal orientation and moderate dimensions, it can be installed indoors in factories, warehouses, or HVAC equipment rooms where stable, efficient ventilation is required.

Q: What safety features are included with this fan model?

A: The fan features an ISI Marked motor with overload protection and Class F insulation, ensuring safe operation under industrial load conditions and reducing the risk of electrical faults.

Q: How does the air-cooled system enhance operation?

A: The air-cooled system helps maintain safe motor temperatures during continuous use, preventing overheating and extending the overall lifespan of the fan.

Q: What are the primary benefits of using this DIDW Centrifugal Fan?

A: Key benefits include high airflow efficiency (up to 85%), durable construction, reliable safety features, low maintenance requirements, and quiet operation (72 dB), making it a cost-effective choice for demanding ventilation needs.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in DIDW Centrifugal Fans Manufacturer in India Category

DIDW Centrifugal Fan 610 MM X 455 MM

DIDW Centrifugal Fan 610 MM X 455 MM

Price 21000 INR

Minimum Order Quantity : 12 Pieces

Orientation : Double Inlet, Double Width

Noise Level : < 85 dB

Usage & Applications : Industrial Ventilation, HVAC Systems, Air Handling Units, Dust Extraction

Automation Grade : SemiAutomatic

DIDW Centrifugal Fan 330 MM X 305 MM

DIDW Centrifugal Fan 330 MM X 305 MM

Price 7500 INR

Minimum Order Quantity : 12 Pieces

Orientation : Double Inlet Double Width

Noise Level : Below 80 dB

Usage & Applications : HVAC, Industrial Ventilation, Air Handling Units

Automation Grade : SemiAutomatic

DIDW Centrifugal Fan 140 MM X 150 MM

DIDW Centrifugal Fan 140 MM X 150 MM

Price 800 INR

Minimum Order Quantity : 12 Pieces

Orientation : Double Inlet Double Width

Noise Level : Less than 75 dB

Usage & Applications : HVAC Systems, Industrial Ventilation, Air Handling Units

Automation Grade : Manual

DIDW Centrifugal Fan 180 MM X 178 MM

DIDW Centrifugal Fan 180 MM X 178 MM

Price 950 INR

Minimum Order Quantity : 12 Pieces

Orientation : Horizontal

Noise Level : <75 dB

Usage & Applications : HVAC, Air Handling Units, Clean Rooms, Air Pollution Control Equipment

Automation Grade : Manual



Back to top