Series DPT Range Differential Pressure Transmitter
Series DPT Range Differential Pressure Transmitter

Series DPT Range Differential Pressure Transmitter

Series DPT Range Differential Pressure Transmitter Specification

  • Grade
  • Industrial
  • Seal Material
  • Silicone or NBR
  • Outer Size
  • Approximately 120 mm x 80 mm x 40 mm
  • Thread
  • 1/8 NPT Female
  • Sensor Type
  • Differential Pressure Sensor
  • Display
  • Digital LCD Display
  • Material
  • ABS Plastic Housing
  • Processing Type
  • Electronic
  • Mount Type
  • Wall or Panel Mount
  • Scale Range
  • 0 to 250 Pa, 0 to 400 Pa, 0 to 1000 Pa (Model-dependent)
  • Accuracy
  • 1% of Full Scale
  • Finishing
  • Powder Coated
  • Measure Pressure Of
  • Air and Non-corrosive Gases
  • Accessories
  • Mounting Screws, Instruction Manual
 

Series DPT Range Differential Pressure Transmitter Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, Middle East, Africa, Western Europe, Central America, South America, Asia, Eastern Europe, North America
  • Main Domestic Market
  • All India
 

About Series DPT Range Differential Pressure Transmitter

Series DPT Selectable Range Differential Pressure Transmitter

The Series DPT Multi-Range Differential Pressure Transmitter was designed specifically for the building automation and HVAC industry. With field selectable ranges down to 0.1 inches w.c., this product is ideal for monitoring building pressure, static pressure, differential pressure, or air velocity and flow. The Series DPT Differential Pressure Transmitter also has jumper selectable outputs for 4-20 mA or 0-10 V and unit selection giving additional flexibility. For a virtually maintenance free transmitter, order the optional automatic zero and the transmitter will perform its own zero point maintenance. The Multi-Range Differential Pressure Transmitter also has an optional backlit LCD for giving local indication.

Specification

Maximum Pressure:    100 in w.c.
Media compatibility:    Dry air or non-aggressive gases

Accuracy:

  •     Ranges < 0.5 in w.c. = +/- 0.01 in w.c.
  •     Ranges 0.5 in w.c. = +/- 1.5%
  •     includes thermal effects, linearity, hysteresis,   repeatability, and long term stability.
Temperature Ranges:
  •     Compensated: 14 to 122F
  •     Operating: 14 to 122F
Response Time:    0.8 - 4.0, jumper selectable
Power Supply:    24 VDC or VAC, +/- 10%
Output:
  •     Voltage: 3-wire 0 - 10V or 0 - 5V, jumper selectable
  •     Power Consumption: <1.0W
  •     Minimum Resistance: 1k
  •     Current: 3-wire4 - 20mA
  •     Power Consumption: <1.2W
  •     Maximum Load: 500

Enclosure Rating:    IP 54/ NEMA 3
Display:    3 " Digit LCD Backlit LCD
Electrical Connections:    Screw terminal block

MODEL NUMBERS

DPT1-R8 

Range 1

Range 2

Range 3

Range 4

Range 5

Range 6

Range 7

Range 8

inWC 

 -0.1 - 0.1

-0.25 - 0.25 

 -0.5 - .05

 -1.0 - 01.0

0 - 0.1 

0 - 0.25 

0 - 0.5 

0 - 1.0 

 Pa

 -25 - 25

-62 - 62 

 -125 - 125

-250 - 250 

0 - 25 

 0 - 62

0 - 125 

0 - 250 

mbar 

 -0.25 - 0.25

-0.62 - 0.62 

-1.25 - 1.25 

-2.5 - 2.5 

0 - 0.25 

 0 - 0.62

0 - 1.25 

0 - 2.5 

 mmWC

-2.5 - 2.5 

-6.4 - 6.4  

-12.7 - 12.7 

-25.4 - 25.4  

0 - 2.5 

0 - 6.4 

0 - 12.7 

0-25.4 

DPT10-R8 

 

 

 

 

 

 

 

 

 inWC

-0.5 - 0.5 

-2.5 - 2.5 

-5.0 - 5.0 

0 - 0.5 

 0 - 1.0

0 - 2.5 

0 - 5.0 

 0 - 10.0

Pa 

-125 - 125 

-622 - 622 

-1250 - 1250 

 0 - 125

 0 - 250

0 - 622 

0 - 1250 

0 - 2500 

mbar  

-1.25 - 1.25 

-6.2 - 6.2 - 

-12.5 - 12.5 

0 - 1.25 

0 - 2.5 

0 - 6.2 

0 - 12.5 

0 - 25 

 mmWC

-12.7 - 12.7 

-64 - 64 

-127 - 127 

0 - 12.7 

0 - 25.4  

0 - 64 

0 - 127 

 0 - 254

DPT30-R8 

 

 

 

 

 

 

 

 

inWC 

 -5.0 - 5.0

 -10.0 - 10.0

-15.0 - 15.0 

0 - 10 

0 - 15 

0 - 20 

0 - 25 

0 - 30 

 Pa 

-1250 - 1250 

-2500 - 2500 

-3750 - 3750 

 0 - 2500 0

0 - 3750 

0 - 5000 

0 - 6250 

0 - 7500 

mbar  

-12.5 - 12.5 

-25 - 25 

-37.5 - 37.5 

0 - 25 

0 - 37.5 

 0 - 50

0 - 62.5  

0 - 75 

mmWC 

-127 - 127 

-254 - 254 

-380 - 380  

 0 - 254

0 - 380

0 - 508 

0 - 635 

0 - 762 



Precise Differential Pressure Measurement

This transmitter utilizes an advanced differential pressure sensor to deliver accurate readings for air and non-corrosive gases. With an accuracy level of 1% of full scale and selectable scale ranges, it provides reliable monitoring tailored to specific application needs in HVAC, clean rooms, and industrial environments.


Versatile Output and Easy Installation

Supporting both 4-20 mA and 0-10 VDC output signals, the device seamlessly integrates into existing control systems. Its compact outer size and screw terminal connections make installation swift, whether wall-mounted or panel-mounted. The rugged ABS housing and powder-coated finish ensure durability and long-term performance.


Efficient and User-Friendly Operation

The digital LCD display offers a clear overview of measurements, while manual zero and span adjustments enable fine-tuning for precise control. With a rapid response time of less than one second and IP54 protection against dust and moisture, the transmitter is engineered for demanding industrial settings.

FAQs of Series DPT Range Differential Pressure Transmitter:


Q: How do I install the Series DPT Range Differential Pressure Transmitter?

A: To install the transmitter, secure it to a wall or panel using the included mounting screws. Connect wiring through the screw terminals, ensuring compliance with the 24V AC/DC power supply specification. Refer to the instruction manual for detailed step-by-step guidance.

Q: What types of media can be measured with this pressure transmitter?

A: The device is designed to measure the differential pressure of air and non-corrosive gases only. It should not be used with corrosive gases or liquids, as this may damage the sensor and housing.

Q: When should I manually adjust the zero offset and span?

A: Manual zero offset and span adjustments are useful during initial installation, or when calibrating the device to compensate for environmental changes or sensor drift. Adjustments ensure measurement accuracy within the desired application.

Q: Where can I mount the differential pressure transmitter?

A: The transmitter is suitable for either wall or panel mounting. Choose a location within the specified operating temperature range (-20C to +70C) and protected from excessive dust and moisture, considering its IP54 ingress rating.

Q: What benefits does the digital LCD display offer?

A: The digital LCD display provides a clear visual indication of measured differential pressures, facilitating quick diagnostics and easy monitoring by personnel without specialized equipment.

Q: How is the output signal from the transmitter integrated into control systems?

A: You can select either a 4-20 mA or a 0-10 VDC output signal, depending on your systems requirements. This output can be connected to data acquisition systems, PLCs, or building management systems for automated control and monitoring.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series DPT Differential Pressure Transmitter India Category

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -0.25 - 0.25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.25 - 0.25 mbar

Thread : 6 mm hose connection

Scale Range : 0.25 to 0.25 mbar

Measure Pressure Of : Other, Air and noncorrosive gases

Finishing : Other, ABS plastic housing, white finish

Outer Size : Approx. 90 x 90 x 36 mm

Display : Analog

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 75 mbar

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 75 mbar

Thread : 1/8 inch NPT

Scale Range : 0 75 mbar

Measure Pressure Of : Other, Air and Noncorrosive Gases

Finishing : Other, Powder Coated

Outer Size : Approx. 129.5 x 80 x 49 mm (L x W x H)

Display : Digital

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -2.5 - 2.5 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -2.5 - 2.5 mmWC

Thread : Pushon Barbed Fittings

Scale Range : 2.5 to 2.5 mmWC

Measure Pressure Of : Other, Air and Noncorrosive Gases

Finishing : Other, Textured Plastic Enclosure

Outer Size : 90 x 90 mm (Front Panel)

Display : Digital

Sensocon USA Differential Pressure Transmitter Series DPT10-R8  - Range  -2.5 - 2.5 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -2.5 - 2.5 inWC

Thread : 1/8 NPT

Scale Range : 2.5 to 2.5 inWC (Inches of Water Column)

Measure Pressure Of : Other, Air and Noncorrosive Gases

Finishing : Other, Black matte housing

Outer Size : Refer datasheet

Display : None (Transmitter output only)