Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  -380 - 380 mmWC
Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  -380 - 380 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range -380 - 380 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range -380 - 380 mmWC Specification

  • Outer Size
  • 128 x 90 x 53 mm (L x W x D)
  • Thread
  • 1/8 NPT Female
  • Grade
  • Industrial
  • Seal Material
  • Synthetic Rubber (NBR)
  • Display
  • Digital LCD Display
  • Sensor Type
  • Differential Pressure Transmitter
  • Material
  • ABS Plastic Enclosure
  • Processing Type
  • Solid State Electronics
  • Mount Type
  • Surface or Wall Mount
  • Scale Range
  • -380 to 380 mmWC
  • Accuracy
  • 1% of Full Scale
  • Finishing
  • Powder Coated
  • Measure Pressure Of
  • Air and Non-corrosive Gases
  • Accessories
  • Mounting Hardware, Instruction Manual
 

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range -380 - 380 mmWC Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash Advance (CA), Cash in Advance (CID), Cheque
  • Main Export Market(s)
  • Australia, North America, South America, Eastern Europe, Western Europe, Middle East, Africa, Central America, Asia
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range -380 - 380 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  -380 - 380 mmWC
 

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Superior Differential Pressure Measurement

The DPT30-R8 offers reliable monitoring of differential pressures from -380 to 380 mmWC with high accuracy (1% of full scale). Its solid state electronics ensure fast response times and consistent performance, making it ideal for sensitive HVAC, cleanroom, and process automation applications where accuracy is essential.


User-Friendly Design and Installation

With its digital LCD display, external push button for zero and span adjustment, and screw terminal blocks, the DPT30-R8 simplifies setup and routine maintenance. The unit includes all necessary mounting hardware, supports surface or wall mounting options, and is designed for ease of integration into existing systems.


Rugged and Reliable Construction

Housed in a robust, powder-coated ABS plastic enclosure with an IP65 rating, the DPT30-R8 is built to withstand demanding industrial environments. Its synthetic rubber (NBR) seals and non-corrosive materials make this unit suitable for long-term use with air and non-corrosive gases.

FAQs of Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range -380 - 380 mmWC:


Q: How does the Series DPT30-R8 Differential Pressure Transmitter operate?

A: The Series DPT30-R8 measures the difference in pressure between its two ports and outputs a corresponding 4-20 mA analog signal for monitoring or control. Its solid state electronics ensure rapid response times, accurately reflecting changes in air or non-corrosive gas pressures.

Q: What are the typical applications for the DPT30-R8 transmitter?

A: This transmitter is commonly used in HVAC systems, clean rooms, filter monitoring, and fan or pump control. It is suitable for any industrial setting requiring precise measurement of differential pressure in air or non-corrosive gas environments.

Q: When should I perform zero and span adjustment on the device?

A: Zero and span adjustments should be carried out during installation or routine calibration checks. The external push buttons make this process simple, ensuring the transmitter maintains optimal accuracy over its operational lifespan.

Q: Where can the DPT30-R8 transmitter be installed?

A: It can be mounted on a surface or wall close to the area where differential pressure needs to be measured. Its compact design and IP65 enclosure allow it to be used in both protected indoor and industrial areas with mild exposure to dust and moisture.

Q: What process connections does the DPT30-R8 support?

A: The transmitter features two female 1/8" NPT ports for easy connection to pressure lines. These connections are compatible with standard pneumatic fittings used in industrial and HVAC applications.

Q: What are the benefits of using the DPT30-R8 in industrial applications?

A: Benefits include high accuracy, fast response time, robust construction, ease of calibration, digital LCD readout, and compatibility with standard industrial control systems, resulting in improved system monitoring and energy efficiency.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series DPT Differential Pressure Transmitter India Category

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -1.25 - 1.25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -1.25 - 1.25 mbar

Processing Type : Other, Electronic

Seal Material : Silicone

Display : Digital

Measure Pressure Of : Other, Air and Noncorrosive Gases

Sensor Type : Differential Pressure Sensor

Accuracy : 1% of Full Scale

Sensocon USA Series DPT1-R8 - Range -0.25 - 0.25 in WC

Sensocon USA Series DPT1-R8 - Range -0.25 - 0.25 in WC

Processing Type : Other, Electronic

Seal Material : Silicone

Display : LCD Digital

Measure Pressure Of : Other, Air and Noncorrosive Gases

Sensor Type : Differential Pressure Sensor

Accuracy : 1% of Full Scale

Sensocon USA Differential Pressure Transmitter Series DPT10-R8  - Range   0 - 1.0 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 1.0 inWC

Processing Type : Other, Electronic

Seal Material : Silicone

Display : No display (Transmitter only)

Measure Pressure Of : Other, Air and Noncorrosive gases

Sensor Type : Differential Pressure Transmitter

Accuracy : 1% of Full Scale

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -0.62 - 0.62 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.62 - 0.62 mbar

Processing Type : Other, Microprocessor Based

Seal Material : Silicone

Display : LED Display

Measure Pressure Of : Other, Air and NonCorrosive Gases

Sensor Type : Differential Pressure Transmitter

Accuracy : 1% F.S.



Back to top