About Galaxy Magnehelic Gauge Model G2000-50MM Range 0-50 MM WC
Technical Specification
- Pressure Limits: 20 Fig to 15 PSI (-0.677 bar to 1.034 bar)
- Media Compatibility: Air and compatible gasses
- Accuracy: +1- 2% full scale (+/- 3% an -0 and +/-4% on -00) throughout range at 70 F (21 C)
- Temperature Ranges: 20 to 140 F (-7 to 60 C)
- Housing Material: Die cast aluminum case and bezel (ABS for P2000), with acrylic cover
- Process Connection:1/8 female NPT duplicate high and low pressure taps one pair side and one pair back.
- Weight: 1 lb 2 oz (510 g)
- Accessories: Two 1/8 NPT barbed frftings,two 1/8 NPT plugs, and three mounting tabs and screws
- Warranty: 2 years Approvals: Roi-IS, CE
Precision Differential Pressure MeasurementThe G2000-50MM Magnehelic Gauge is specifically designed to measure differential pressure in air and non-corrosive gases, making it suitable for various industrial applications. Its analog display and 50 mm dial provide clear, accurate readings, facilitating effective monitoring in ventilation, filtration, and air control systems.
Robust Construction for Industrial EnvironmentsConstructed from die-cast aluminum with a corrosion-resistant, powder-coated finish, the gauge withstands harsh conditions and offers a long service life. The clear acrylic window and silicone rubber seals provide additional durability and protection, ensuring consistent performance across a wide temperature range.
User-Friendly Operation and MaintenanceFeaturing an external adjustment screw for zero setting and simple surface mounting, the G2000-50MM offers easy installation and maintenance. All necessary accessories, including mounting screws and tubing adapters, are included for hassle-free setup, making it user-friendly for operators and technicians alike.
FAQs of Galaxy Magnehelic Gauge Model G2000-50MM Range 0-50 MM WC:
Q: How is the Galaxy Magnehelic Gauge Model G2000-50MM installed?
A: This gauge is designed for surface mounting in a vertical orientation. The package includes two mounting screws and two plastic tubing adapters for easy connection and secure installation. Process connections are 1/8 inch NPT female for both high and low pressure ports.
Q: What types of media can I measure with the G2000-50MM Magnehelic Gauge?
A: The gauge is suitable for measuring air and non-corrosive gases. It is not recommended for use with liquids or corrosive media due to its material construction and design.
Q: When is zero adjustment necessary, and how is it performed on this gauge?
A: Zero adjustment is recommended after installation or whenever readings appear inaccurate. The gauge features an external adjustment screw, allowing users to reset the zero point without disassembling the equipment.
Q: Where should this gauge be used for optimal performance?
A: The G2000-50MM functions best in industrial environments monitoring ventilation, filtration, or airflow systems, provided that the surrounding conditions are within its temperature range of -20C to +60C and do not expose the gauge to aggressive chemicals.
Q: What are the benefits of the clear acrylic window and die-cast aluminum case?
A: The clear acrylic window offers excellent visibility of the dial and pointer, while the die-cast aluminum case with powder-coated finish protects against corrosion, impact, and harsh industrial conditions, ensuring reliability and longevity.
Q: How does overpressure protection work for this model?
A: The G2000-50MM includes overpressure protection up to 15 PSI (1.03 bar) to prevent damage in case of accidental excess pressure, preserving the internal mechanism and maintaining accurate measurements.