About Dwyer USA Model 2030 Magnehelic Gage Range 0-30 Inch WC
Dwyer USA Model 2030 Magnehelic Gage Range 0-30 Inch WC
Description
Dwyer 2030 Differential pressure gage, range 0-30" w.c. (inches of water), minor divisions 1.0.
Using Dwyer's simple, frictionless Magnehelic Gage movement, it quickly indicates low air or non-corrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It's inexpensive, too.
The Magnehelic Gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment.
Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.
Features
- Bezel provides flange for flush mounting in panel.
- Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale.
- Precision litho-printed scale is accurate and easy to read.
- Red tipped pointer of heat treated aluminum tubing is easy to see. It is rigidly mounted on the helix shaft.
- Pointer stops of molded rubber prevent pointer over-travel without damage.
- "Wishbone" assembly provides mounting for helix, helix bearings and pointer shaft.
- Jeweled bearings are shock-resistant mounted; provide virtually friction-free motion for helix. Motion damped with high viscosity silicone fluid.
- Zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness.
- Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the magnetic field to move the pointer across the scale.
- Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkages.
- Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reacts to pressure on diaphragm. Live length adjustable for calibration.
- Silicone rubber diaphragm with integrally molded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures.
- Die cast aluminum case is precision made and iridite-dipped to withstand 168 hour salt spray corrosion test. Exterior finished in baked dark gray hammerloid. One case size is used for all standard pressure options, and for both surface and flush mounting.
- Blowout plug of silicone rubber protects against overpressure on 15 psig rated models. Opens at approximately 25 psig.
- O-ring seal for cover assures pressure integrity of case.
Robust Construction and Versatile MountingThis gauge is engineered with a die-cast aluminum case and a smooth, baked enamel finish for enhanced durability. It can be flush or surface mounted, offering flexibility in different installation environments. The clear acrylic window ensures unobstructed reading, while external zero adjustment on the front cover allows for straightforward calibration.
Precise Low Differential Pressure MeasurementUtilizing a diaphragm-type sensor, the Model 2030 provides analog readouts for differential pressure of air or compatible gases, with an accuracy of 2% of full scale. It is factory calibrated and rigorously leak tested, making it ideal for critical HVAC, filter monitoring, and cleanroom applications.
FAQs of Dwyer USA Model 2030 Magnehelic Gage Range 0-30 Inch WC:
Q: How do I install the Dwyer Model 2030 Magnehelic Gage?
A: You can mount the Model 2030 on a surface or flush using the included mounting adapters and screws. The standard process connections are located on the sides, with optional back connection. Simply use the 1/8 NPT female side ports, and utilize the included pipe thread to rubber tubing adapters if needed.
Q: What types of media can be measured with this gage?
A: The Model 2030 is designed specifically for measuring low differential pressure of air and compatible non-corrosive gases. It should not be used with liquids or corrosive gases to ensure long-term reliability and accuracy.
Q: When should I perform zero adjustment, and how is it done?
A: Zero adjustment should be performed initially during installation or if you notice the pointer is off zero when the pressure connections are open to atmosphere. Simply turn the external screw adjustment on the front cover until the needle aligns with zero on the scale.
Q: Where can this gage operate effectively?
A: This gage operates reliably in environments with temperatures ranging from -7C to +60C (20F to 140F), making it suitable for indoor industrial, laboratory, or HVAC applications across varying climates.
Q: What is the benefit of a mechanical dial display?
A: The analog mechanical dial provides a clear, real-time visual indication of pressure differences without requiring any electrical power, which ensures continuous operation even in power outages and easy readings at a glance.
Q: How does the Dwyer 2030 ensure measurement accuracy and reliability?
A: Every unit is factory calibrated and leak tested. The precision-balanced aluminum pointer, rugged diaphragm sensor, and well-crafted scale guarantee repeatable accuracy within 2% of the full scale range.