Dwyer USA Magnehelic Gauges 0 To 125 MM WC
Dwyer USA Magnehelic Gauges 0 To 125 MM WC

Dwyer USA Magnehelic Gauges 0 To 125 MM WC

Dwyer USA Magnehelic Gauges 0 To 125 MM WC Specification

  • Seal Material
  • Silicone / Buna-N
  • Display
  • Analog Dial
  • Sensor Type
  • Diaphragm
  • Thread
  • 1/8 NPT Female
  • Outer Size
  • 110 mm approx.
  • Grade
  • Industrial
  • Material
  • Die-cast Aluminum Case, Acrylic Lens
  • Dial Material
  • White Aluminum Dial with Black Markings
  • Pointer Material
  • Precision Balanced Aluminum Pointer
  • Processing Type
  • Precision-Machined
  • Diameter
  • 4 inches (101.6 mm)
  • Glass Size
  • Full View Acrylic Lens
  • Mount Type
  • Surface / Flush Mount
  • Scale Range
  • 0 To 125 MM WC (Water Column)
  • Accuracy
  • 2% of Full Scale
  • Finishing
  • Textured Black Case
  • Measure Pressure Of
  • Low Air or Non-Corrosive Gas Pressure
  • Accessories
  • Two mounting brackets, three tubing connectors, and instruction sheet
 

Dwyer USA Magnehelic Gauges 0 To 125 MM WC Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, North America, Eastern Europe, Middle East, Western Europe, Africa, Central America, South America, Asia
  • Main Domestic Market
  • All India
 

About Dwyer USA Magnehelic Gauges 0 To 125 MM WC

Dwyer USA Magnehelic Gauges 0 To 125 MM WC

INCLUDES

Two 1/8" NPT plugs, two 1/8" rubber tubing adapters, and three mounting adapters with screws

MORE ABOUT THIS ITEM

The Magnahelic guage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems, and pressures in fluid amplifier or fluidic systems. The gauge's motion is damped with high-viscosity silicone fluid. The zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness. Rugged design resists shock, vibration, and overpressure.

The helix is precision-made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the maganetic field to move the pointer across the scale. The samarium cobalt magnet is mounted at one end of the range spring and rotates the helix without mechanical linkages.

Specifications & Description 

 

 Accuracy±2% full-scale
 Dial Size (in)
 Dial Size (mm)102 
Min Pressure (in WC)
 Max Pressure (in WC)10 
Wetted Materials Aluminum
 Case Aluminum
 Lens Materialacrylic
 Process Connection1/8" NPT
 Unit Of Measurement " WC
 Displayanalog dial
 Media Compatibility Gases and liquids compatible with wetted materials
 Resolution 0.20
 Description Magnehelic Differential Pressure Gauge, Type , 0 to 125 MM WC
 


Precision Measurement for Critical Environments

The Dwyer Magnehelic Gauge is tailored for applications demanding accurate monitoring of low-pressure gases, such as in cleanrooms, HVAC systems, and filter monitoring stations. Its robust sensor and quick response ensure real-time, reliable data for process control and safety.


Durable Design for Industrial Use

Constructed from die-cast aluminum with a textured black finish and a full-view acrylic lens, the gauge offers longevity even in harsh industrial environments. The external zero adjustment screw simplifies calibration, and the IP50 rating shields against dust and particle ingress.


Flexible Installation and User-Friendly Operation

Mount the Magnehelic Gauge easily with supplied brackets, using either the surface or flush-mount method. Two back and two side 1/8" NPT ports accommodate a variety of setups. The clearly marked analog dial and external adjustments make pressure monitoring and recalibration both straightforward and efficient.

FAQs of Dwyer USA Magnehelic Gauges 0 To 125 MM WC:


Q: How do I install the Dwyer Magnehelic Gauge model 2000-125 MM WC?

A: Installation is simple: use the supplied mounting brackets for surface or flush mounting, connect tubing to any of the two back or two side 1/8" NPT ports, and follow the included instruction sheet for guidance. Ensure all connections are secure before use.

Q: What maintenance does the Magnehelic Gauge require and how do I zero-adjust it?

A: Routine maintenance involves periodic inspection for dust or debris and verifying calibration. Zero adjustment is easily performed by turning the external screw adjustment on the gauges face to align the pointer with zero when no pressure is applied.

Q: When should the Dwyer Magnehelic Gauge be used in an HVAC system?

A: The gauge is recommended for continuous monitoring of air filter conditions, duct pressure, or room pressurization in HVAC systems. Use it whenever reliable, real-time pressure data is necessary for efficient system operation and preventive maintenance.

Q: Where can this gauge be effectively utilized beyond HVAC systems?

A: Beyond HVAC applications, the Magnehelic Gauge excels in cleanroom pressure monitoring, laboratory environments, air velocity measurement, and any setting where precise measurement of low non-corrosive gas pressure is vital.

Q: What benefits does the analog dial provide over digital alternatives?

A: An analog dial delivers immediate, easy-to-read pressure values without the need for batteries or complex electronics, ensuring reliability in industrial settings and quick pressure assessment at a glance.

Q: How does the gauge protect against overpressure or harsh environments?

A: The die-cast aluminum casing with a textured black finish and IP50 ingress protection defends against dust. It also tolerates overpressure up to 172 kPa (25 psi), maintaining accuracy and longevity in challenging conditions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Sensocon - Dwyer S2000 Differential Pressure Gauge Category

Dwyer 2300-2KPA Magnehelic Differential Pressure Gauge

Dwyer 2300-2KPA Magnehelic Differential Pressure Gauge

Minimum Order Quantity : 12 Pieces

Diameter : 4 inches (101.6 mm)

Pointer Material : Other, Red tipped aluminum

Mount Type : Other, Surface or flush mount

Grade : Industrial Grade

Processing Type : Other, Factory Calibrated

Dwyer 2002- AV Magnehelic Differential Pressure Gauge

Dwyer 2002- AV Magnehelic Differential Pressure Gauge

Minimum Order Quantity : 12 Pieces

Diameter : 4 inches (101.6 mm)

Pointer Material : Other, Precision Balanced

Mount Type : Other, Surface or Flush Mount

Grade : Industrial

Processing Type : Other, Casting and Machining

Dwyer USA Model 2050 Magnehelic Gage Range 0-50 Inch WC

Dwyer USA Model 2050 Magnehelic Gage Range 0-50 Inch WC

Minimum Order Quantity : 12 Pieces

Diameter : 4.5 inches (114 mm)

Pointer Material : Other, Black aluminum

Mount Type : Other, Surface or flush mounting

Grade : Industrial

Processing Type : Other, Precisionengineered / Factory calibrated

Dwyer 2203 Magnehelic Differential Pressure Gauge 0-3 PSI

Dwyer 2203 Magnehelic Differential Pressure Gauge 0-3 PSI

Minimum Order Quantity : 12 Pieces

Diameter : 4 inch (101.6 mm)

Pointer Material : Other, Red adjustable pointer

Mount Type : Other, Surface or flush mount

Grade : Industrial Grade

Processing Type : Other, Precision engineered



Back to top