About Dwyer TDS112 Thermal Dispersion Flow Switch
Dwyer TDS112 Thermal Dispersion Flow Switch
Adjustable Switch Point LED IndicationThe Series TDS Thermal Dispersion Flow Switch offers solid state flow detection of non-coating liquids for pump and process protection. SPDT output allows for interfacing with remote PLC or relay control Device. The adjustable switch point is factory calibrated at 0.2 fps with LED indication of flow and calibration status. Units feature selectable NO or NC Operation and Are not damaged by over Ranging Flow Velocities.
Models & Ordering
| Model | Description |
| TDS112 | Thermal dispersion flow switch PP/PPS wetted parts 3.0" (7.6 cm) length. |
| TDS122 | Thermal dispersion flow switch PP/PPS wetted parts 4.5" (11.4 cm) length. |
| TDS212 | Thermal dispersion flow switch PVDF wetted parts 3.0" (7.6 cm) length. |
| TDS222 | Thermal dispersion flow switch PVDF wetted parts 4.5" (11.4 cm) length. |
Specifications
Service: Liquids.
Wetted Materials: Polypropylene/PPS or Polyvinylidene Fluoride.
Range: Range: 0.04 to 10 fps (1.2X10-2 to 3.05 m/s)
Temperature Limits: 32 to 140F (0 to 60C).
Pressure Limits: 150 psi (10 bar) @ 77F (25C) derated @ 1.667 psi (.113 bar) per C above 25C.
Repeatability: 5% of setpoint.
Switch Type: SPDT.
Electrical Rating: 60 VAC/60 VDC @ 1 A.
Electrical Connections: 22 AWG 3-wire 10 ft (3 m) length.
Process Connections: 3/4" male NPT.
Mounting Orientation: Any orientation for pipe sizes 3/4" to 1-1/2" use 3.0" (7.6 cm) length switch; for 2" to 16" pipe sizes use 4.5" (11.4 cm) length switch.
Setpoint Adjustment: 0.04 to 3 fps (1.2X10-2 to .91 m/s).
Setpoint Drift: 0.5% of setpoint.
Response Time: 1-10 seconds.
Viscosity Range: 1 to 200 centipoise.
Supply Voltage: 12 to 36 VDC.
Consumption: 50 mA (nominal).
Indication: LED for flow status.
Weight: 3 oz (94 g).
Agency Approvals: CE.
Industrial-Grade ReliabilityManufactured with a rugged 316 stainless steel probe and Viton seals, the Dwyer TDS112 withstands harsh process conditions and is suitable for a wide range of industrial liquid applications. Its IP66/IP67 rating ensures robust protection against environmental hazards, making it a dependable choice for challenging installations.
Versatile and Precise OperationThe TDS112 offers a fully adjustable flow set point and an adjustable response time, ensuring flexibility in various liquid monitoring scenarios. With factory calibration, the sensor delivers reliable and precise measurements with 2% accuracy and excellent repeatability. The SPDT relay output enhances integration with process control systems.
Simple Installation and Status MonitoringInstallation is quick and convenient, thanks to the M12 plug connection and included mounting hardware. LED indicators provide immediate feedback on device status, and the comprehensive instruction manual supports effortless commissioning and on-site adjustments.
FAQs of Dwyer TDS112 Thermal Dispersion Flow Switch:
Q: How is the Dwyer TDS112 flow switch installed and connected electrically?
A: The TDS112 is an insertion-type flow switch designed for quick installation using its 3/4 NPT threaded connection. Electrical connection is established via a 4-pin M12 plug, which is compatible with standard industrial connectors. All necessary mounting hardware is included, and the IP66/IP67 enclosure assists with robust, long-term installation.
Q: What types of media can the TDS112 monitor, and are there any restrictions?
A: This sensor is intended for use with compatible liquids only. It is not suitable for gases or particulates. The materials used316 stainless steel and Viton sealsoffer excellent corrosion resistance in most industrial liquid applications.
Q: When should I adjust the response time or set point on my TDS112 flow switch?
A: Adjust the response time (between 1 and 10 seconds) to suit the dynamics of your specific process and to filter out brief flow fluctuations. The set point can be calibrated over the full flow range, allowing for customization to your desired flow threshold.
Q: Where can I use the TDS112 flow switch for optimal performance?
A: Install the TDS112 in liquid flow lines where robust monitoring is needed, such as cooling systems, pump protection, or process control loops. Ensure the process temperature is between -40C and 85C and the pressure does not exceed 40 bar for safe operation.
Q: What is the process for verifying correct operation and troubleshooting the flow switch?
A: LED status indicators on the unit provide immediate feedback, showing whether flow is present or absent based on your set point. The included instruction manual details step-by-step procedures for calibration, adjustment, and troubleshooting if abnormal performance is observed.
Q: How does using the TDS112 benefit my industrial process monitoring?
A: The TDS112 delivers fast, accurate flow detection with minimal maintenance due to its non-moving thermal dispersion principle, robust construction, and reliable relay output. This ensures improved process safety and equipment protection in critical applications.