Dwyer EDPS-03-1-N Adjustable Differential Pressure Switch
Dwyer EDPS-03-1-N Adjustable Differential Pressure Switch

Dwyer EDPS-03-1-N Adjustable Differential Pressure Switch

Dwyer EDPS-03-1-N Adjustable Differential Pressure Switch Specification

  • Grade
  • Industrial
  • Sensor Type
  • Differential Pressure Switch
  • Outer Size
  • 2.56 x 3.12 x 1.5 (65 x 79 x 38 mm)
  • Display
  • No Display
  • Seal Material
  • EPDM
  • Thread
  • 1/8 NPT Female
  • Material
  • Polycarbonate
  • Processing Type
  • Injection Molded Housing
  • Mount Type
  • Surface Mount
  • Scale Range
  • 0.08 to 1.2 in w.c. (20 to 300 Pa)
  • Accuracy
  • 15% at Set Point
  • Finishing
  • Polycarbonate Enclosure
  • Measure Pressure Of
  • Air and Compatible Gases
  • Accessories
  • Mounting Screws, Installation Manual
 

Dwyer EDPS-03-1-N Adjustable Differential Pressure Switch Trade Information

  • Payment Terms
  • Cash Against Delivery (CAD), Cash on Delivery (COD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, North America, Eastern Europe, Middle East, Western Europe, South America, Asia, Central America, Africa
  • Main Domestic Market
  • All India
 

About Dwyer EDPS-03-1-N Adjustable Differential Pressure Switch

Dwyer EDPS-03-1-N Adjustable Differential Pressure Switch

Adjustable differential pressure switch, range .20-2.00" w.c., with M20 connection.


The Series EDPS Adjustable Differential Pressure Switch is designed for pressure, vacuum, and differential pressures. The dual scaled adjustment knob in inches water column and pascals allows changes to the switching pressure to be made without a pressure gage. The EDPS is available with settings from 0.08" w.c. (20 Pa) up to 16" w.c. (4000 Pa). The silicone diaphragm and PA 6.6 body make the series EDPS ideal for use with air and other noncombustible gases. The compact size, adjustment knob and meeting the UL508 standard make the EDPS the perfect choice for H.V.A.C. applications.


Product Applications

  • Monitoring air filters and ventilators.
  • Monitoring industrial cooling-air circuits.
  • Overheating protection for fan heaters.
  • Monitoring flows in ventilation ducts.
  • Controlling air and fire-protection dampers.
  • Frost protection for heat exchanges




Versatile Pressure Monitoring Solution

Designed for a range of industrial applications, the EDPS-03-1-N allows for effective monitoring of air and compatible gases. Typical uses include filter and fan status checks in air handling units, providing reliable differential pressure readings with adjustable set points and simple surface mounting.


Precise External Adjustment

Easily set pressure thresholds with the external screw, allowing calibration without disassembly. The snap-action SPDT switch ensures quick and accurate response to pressure changes, enhancing system control and safety in demanding conditions.


Robust Design and Efficient Installation

The polycarbonate enclosure offers IP54 protection from dust and splashes. Its compact, injection-molded housing and mounting accessories simplify setup, while the screw terminal connections facilitate straightforward, secure wiring for speedy installation.

FAQs of Dwyer EDPS-03-1-N Adjustable Differential Pressure Switch:


Q: How is the set point of the EDPS-03-1-N adjusted for different pressure requirements?

A: The set point is adjusted externally via a screw mechanism on the device, allowing users to precisely calibrate the differential pressure threshold without opening the enclosure.

Q: What applications is the Dwyer EDPS-03-1-N most suitable for?

A: It is ideal for monitoring air and compatible gases in industrial settings, such as filter monitoring, fan monitoring, and managing air handling units, ensuring efficient and safe operation.

Q: When should the differential pressure switch be used in an HVAC system?

A: Install the switch in instances where continual monitoring of pressure differences is neededlike tracking filter status or fan performanceto help prevent system inefficiencies or potential failures.

Q: Where should the EDPS-03-1-N be mounted for best performance?

A: Mount the switch on a stable surface near the monitored pressure source, ensuring accessible placement for wire connections and easy adjustment of the set point using the external screw.

Q: What is the process for wiring the EDPS-03-1-N in an electrical circuit?

A: Electrical connections are made using the integrated screw terminals, following the installation manual provided. This ensures secure integration with 250 VAC circuits at up to 1.5A, suitable for industrial setups.

Q: How does the switch benefit air handling and filtration systems?

A: By providing timely alerts to variations in differential pressure, the EDPS-03-1-N enhances preventative maintenance, reduces downtime, and helps optimize system efficiency and safety.

Q: What is the protection class and operating temperature range of this pressure switch?

A: The EDPS-03-1-N features IP54 protection against dust and water splashes, and operates reliably within a temperature range of -20C to 85C (-4F to 185F).

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in ADPS EDPS Differential Pressure Switch Wholesaler Category

Dwyer BDPA-08-2-N Adjustable Differential Pressure Switch

Dwyer BDPA-08-2-N Adjustable Differential Pressure Switch

Material : Other, Stainless Steel / Pressure Cast Aluminum

Grade : Industrial

Accuracy : 2% of Full Scale

Outer Size : 125 mm (Approximate)

Mount Type : Other, Panel Mount

Measure Pressure Of : Other, Air, Noncorrosive Gases

Dwyer Air Filter Kit A - 481

Dwyer Air Filter Kit A - 481

Material : Other, ABS Plastic, Metal

Grade : Industrial

Accuracy : High

Outer Size : Compact

Mount Type : Other, Panel Mount

Measure Pressure Of : Other, Air

Dwyer BDPA-03-2-N Adjustable Differential Pressure Switch

Dwyer BDPA-03-2-N Adjustable Differential Pressure Switch

Material : Other, Aluminum Case, Brass Wetted Parts

Grade : Industrial

Accuracy : 0.5% of F.S.

Outer Size : 108 x 98 x 58 mm (approx.)

Mount Type : Other, Wall Mount

Measure Pressure Of : Other, Air and Noncorrosive Gases

Sensocon USA Differential Pressure Switch Series 104 - 2 Pressure Range 50-500 Pa

Sensocon USA Differential Pressure Switch Series 104 - 2 Pressure Range 50-500 Pa

Material : Other, ABS Housing

Grade : Industrial Grade

Accuracy : 1.5% F.S.

Outer Size : Approx. 105 mm x 85 mm x 58 mm

Mount Type : Other, Wall Mounting

Measure Pressure Of : Other, Air and NonAggressive Gases



Back to top