Dwyer A3300-3KPA Photohelic Pressure Switch Gauge Range 1.5-0-1.5 kPa. Dwyer A3300-3KPA Photohelic Pressure Switch Gauge Range 1.5-0-1.5 kPa. Dwyer A3300-3KPA Photohelic Pressure Switch Gauge Range 1.5-0-1.5 kPa. Dwyer A3300-3KPA Photohelic Pressure Switch Gauge Range 1.5-0-1.5 kPa. Dwyer A3300-3KPA Photohelic Pressure Switch Gauge Range 1.5-0-1.5 kPa. Dwyer A3300-3KPA Photohelic Pressure Switch Gauge Range 1.5-0-1.5 kPa.
Dwyer A3300-3KPA Photohelic Pressure Switch Gauge Range 1.5-0-1.5 kPa.
Dwyer A3300-3KPA Photohelic Pressure Switch Gauge Range 1.5-0-1.5 kPa. Dwyer A3300-3KPA Photohelic Pressure Switch Gauge Range 1.5-0-1.5 kPa. Dwyer A3300-3KPA Photohelic Pressure Switch Gauge Range 1.5-0-1.5 kPa. Dwyer A3300-3KPA Photohelic Pressure Switch Gauge Range 1.5-0-1.5 kPa. Dwyer A3300-3KPA Photohelic Pressure Switch Gauge Range 1.5-0-1.5 kPa.

Dwyer A3300-3KPA Photohelic Pressure Switch Gauge Range 1.5-0-1.5 kPa.

40000 INR/Piece

Product Details:

  • Display 4" (101.6 mm) Dial Face,5 x 8" (127 x 209.55 MM)
  • Product Type Series A3000
  • Weight 4 lb (1.81 kg) Kilograms (kg)
  • Usage Air And Non Combustible,Compatible Gases
  • Size 4" (101.6 mm) Dial Face,5 x 8" (127 x 209.55 MM)
  • Diameter 4" (101.6 mm) Dial Face,5 x 8" (127 x 209.55 MM) Millimeter (mm)
  • Mount Type Surface
  • Click to View more
X

Dwyer A3300-3KPA Photohelic Pressure Switch Gauge Range 1.5-0-1.5 kPa. Price And Quantity

  • 1 Piece
  • 40000 INR/Piece

Dwyer A3300-3KPA Photohelic Pressure Switch Gauge Range 1.5-0-1.5 kPa. Product Specifications

  • 4 lb (1.81 kg) Kilograms (kg)
  • Air And Non Combustible,Compatible Gases
  • 4" (101.6 mm) Dial Face,5 x 8" (127 x 209.55 MM) Millimeter (mm)
  • 4" (101.6 mm) Dial Face,5 x 8" (127 x 209.55 MM)
  • Series A3000
  • 4" (101.6 mm) Dial Face,5 x 8" (127 x 209.55 MM)
  • Surface
  • A3300-3KPA Range 1.5-0-1.5 kPa.
  • Gas

Dwyer A3300-3KPA Photohelic Pressure Switch Gauge Range 1.5-0-1.5 kPa. Trade Information

  • Cash Against Delivery (CAD) Cash on Delivery (COD) Cash Advance (CA) Cheque Letter of Credit (L/C) Telegraphic Transfer (T/T) Western Union Paypal Letter of Credit at Sight (Sight L/C) Delivery Point (DP) Days after Acceptance (DA) Cash in Advance (CID)
  • Sample costs shipping and taxes has to be paid by the buyer
  • www.envirotechindia.co.in
  • Australia South America Eastern Europe Western Europe Middle East Africa Central America Asia North America
  • Dadra and Nagar Haveli Chandigarh Himachal Pradesh Manipur Andaman and Nicobar Islands Daman and Diu Lakshadweep Chhattisgarh South India East India Assam Arunachal Pradesh Bihar Delhi Gujarat Goa Jammu and Kashmir Jharkhand Karnataka Madhya Pradesh Maharashtra Mizoram Meghalaya Punjab Pondicherry Rajasthan Sikkim Tamil Nadu Telangana Tripura Kerala Nagaland Uttarakhand West Bengal Haryana North India Andhra Pradesh Central India Odisha Uttar Pradesh West India All India
  • YAS

Product Description

Dwyer A3300-3KPA Photohelic Pressure Switch Gauge Range 1.5-0-1.5 kPa.

Dwyer A3300-3KPA Photohelic Pressure Switch/Gauge (1.5-0-1.5 kPa.)

Model: A3300-3KPA

Bezel and front cover (with set point knobs and zero adjustment screw) removed to expose Photohelic® Switch/Gage set point 

Mechanism. Cover is Clear Polycarbonate Plastic. Gage Pointer and Light Shutter Are Mounted on Helix and Balancing 

Counterweight.

Dwyer A3300-3KPA

Features

  • Measure 4 to 20 mA Signals Without "Breaking the Loop"
  • Measure mA Signals For PLC and Control System Analog I/O
  • Dual Backlit Display With Both mA Measurement And Percent of 4 to 20 mA Span
  • Measurement Spotlight illuminates hard to see wires in dark enclosures
  • Detachable clamp with extension cable for measurements in tight locations
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
  • Automatically change the 4 to 20 mA output for remote testing
  • Power saving features, auto-off, backlight timeout extend battery life
  • Hold function captures and displays changing measurements

Applications

  • Air Conditioner Systems
  • Clean Rooms
  • Fume Exhaust Systems
  • Dwyer A3300-3KPA Specifications

Switch Specifications

  • Switch Type:Each Set Point Has 2 Form C Relays (DPDT)
  • Repeatability:±1% of FS
  • Electrical Rating:10 A at 28 VDC,10 A at 120,240 VAC
  • Electrical Connections:Screw Terminals. Use 167°F (75°C) Copper Conductors Only
  • Power Requirements:120 VAC, 50/60 Hz,240 VAC and 24 VAC power optional
  • Mounting Orientation:Diaphragm in Vertical Position. Consult Factory For Other Position Orientations
  • Set Point Adjustment:Adjustable Knobs On Face
  • Agency Approvals:CE, CSA, UL

Gauge Specifications

  • Service:Air And Non Combustible,Compatible Gases
  • Accuracy:±2% of FS at 70°F (21.1°C),±3% on -0,±4% on -00 models
  • Pressure Limits:-20" Hg to 25 psig (-0.677 to 1.72 bar),MP option; 35 psig (2.41 bar),HP option; 80 psig (5.52 bar)
  • Temperature Limits:20 to 120°F. (-6.67 to 48.9°C),-20 to 120°F (-28 to 48.9°C) with low temperature option
  • Process Connections:? female NPT
  • Dimensions:4" (101.6 mm) Dial Face,5 x 8¼" (127 x 209.55 MM)
  • Weight:4 lb (1.81 kg)

Enter Buying Requirement Details
Email Id
Mobile number

Other Products in 'DWYER Series A3000 Photohelic Pressure Switch-Gage' category



Back to top