Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.
Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.
Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.
Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.
Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.
Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.
Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.
Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.
Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.
Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.
Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.
Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.

Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.

Price 40000 INR/ Piece

MOQ : 1 Piece

Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c. Specification

  • Display
  • 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm)
  • Usage
  • Air and non-combustible, compatible gases
  • Size
  • 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm)
  • Product Type
  • Series A3000
  • Diameter
  • 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm) Millimeter (mm)
  • Weight
  • 4 lb (1.81 kg) Kilograms (kg)
  • Mount Type
  • Surface
  • Scale Range
  • A3030 Range 0-30" w.c.
  • Measure Pressure Of
  • Gas
 

Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c. Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Against Delivery (CAD), Cash on Delivery (COD), Cash Advance (CA), Letter of Credit at Sight (Sight L/C), Telegraphic Transfer (T/T), Western Union, Paypal, Letter of Credit (L/C), Delivery Point (DP), Days after Acceptance (DA), Cash in Advance (CID), Cheque
  • Packaging Details
  • EXTRA
  • Main Export Market(s)
  • Western Europe, Australia, North America, Eastern Europe, Central America, Middle East, South America, Asia, Africa
  • Main Domestic Market
  • Assam, Dadra and Nagar Haveli, Chandigarh, Himachal Pradesh, Uttarakhand, Lakshadweep, South India, Central India, North India, East India, West India, Andaman and Nicobar Islands, Andhra Pradesh, Arunachal Pradesh, Bihar, Delhi, Daman and Diu, Gujarat, Goa, Jammu and Kashmir, Jharkhand, Karnataka, Maharashtra, Mizoram, Meghalaya, Manipur, Nagaland, Punjab, Pondicherry, Rajasthan, Sikkim, Tamil Nadu, Telangana, Tripura, Uttar Pradesh, Haryana, West Bengal, Madhya Pradesh, Kerala, Odisha, Chhattisgarh, All India
  • Certifications
  • YAS
 

About Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.

Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.
Dwyer A3030 Photohelic Pressure Switch/Gauge (0-30"w.c.)
Model: A3030

Bezel and front cover (with set point knobs and zero adjustment screw) removed to expose Photohelic® switch/gage set point mechanism. Cover is clear polycarbonate plastic. Gage pointer and light shutter are mounted on helix and balancing counterweight.

Dwyer A3030 Offers

Features

  • Measure 4 to 20 mA signals without "breaking the loop"
  • Measure mA signals for PLC and control system analog I/O
  • Dual backlit display with both mA measurement and percent of 4 to 20 mA span
  • Measurement Spotlight illuminates hard to see wires in dark enclosures
  • Detachable clamp with extension cable for measurements in tight locations
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
  • Automatically change the 4 to 20 mA output for remote testing
  • Power saving features, auto-off, backlight timeout extend battery life
  • Hold function captures and displays changing measurements

Applications

  • Air Conditioner Systems
  • Clean Rooms
  • Fume Exhaust Systems

Dwyer A3030 Specifications

Switch Specifications

  • Switch Type: Each set point has 2 Form C relays (DPDT)
  • Repeatability: ±1% of FS
  • Electrical Rating: 10 A at 28 VDC,10 A at 120,240 VAC
  • Electrical Connections: Screw terminals. Use 167°F (75°C) copper conductors only
  • Power Requirements: 120 VAC, 50/60 Hz,240 VAC and 24 VAC power optional
  • Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations
  • Set Point Adjustment: Adjustable knobs on face
  • Agency Approvals: CE, CSA, UL

Gauge Specifications

  • Service: Air and non-combustible, compatible gases
  • Accuracy: ±2% of FS at 70°F (21.1°C),±3% on -0,±4% on -00 models
  • Pressure Limits: -20" Hg to 25 psig (-0.677 to 1.72 bar),MP option; 35 psig (2.41 bar),HP option; 80 psig (5.52 bar)
  • Temperature Limits: 20 to 120°F. (-6.67 to 48.9°C),-20 to 120°F (-28 to 48.9°C) with low temperature option
  • Process Connections: ? female NPT
  • Dimensions: 4" (101.6 mm) dial face,5 x 8¼" (127 x 209.55 mm)
  • Weight: 4 lb (1.81 kg)


FAQs of Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.:


Q: What type of pressure can the Dwyer A3030 Photohelic Pressure Switch Gauge measure?

A: The Dwyer A3030 Photohelic Pressure Switch Gauge can measure gas pressure.

Q: What is the mounting type of the Dwyer A3030 Photohelic Pressure Switch Gauge?

A: The mounting type of the Dwyer A3030 Photohelic Pressure Switch Gauge is surface mount.

Q: What is the weight of the Dwyer A3030 Photohelic Pressure Switch Gauge?

A: The weight of the Dwyer A3030 Photohelic Pressure Switch Gauge is 4 lb (1.81 kg).

Q: What is the scale range of the Dwyer A3030 Photohelic Pressure Switch Gauge?

A: The scale range of the Dwyer A3030 Photohelic Pressure Switch Gauge is 0-30" w.c.

Q: What gases is the Dwyer A3030 Photohelic Pressure Switch Gauge compatible with?

A: The Dwyer A3030 Photohelic Pressure Switch Gauge is compatible with air and non-combustible gases.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in DWYER Series A3000 Photohelic Pressure Switch-Gage Category

Dwyer A3300-0 Photohelic Pressure Switch Gauge Range .25-0-.25 Inch w.c

Dwyer A3300-0 Photohelic Pressure Switch Gauge Range .25-0-.25 Inch w.c

Price 40000 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Air and noncombustible, compatible gases

Weight : 4 lb (1.81 kg) Kilograms (kg)

Size : 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm)

Scale Range : A33000 Range .250.25" w.c.

Dwyer A3150 Photohelic Pressure Switch Gauge Range 0-150 Inch w.c.

Dwyer A3150 Photohelic Pressure Switch Gauge Range 0-150 Inch w.c.

Price 40000 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Air and noncombustible, compatible gase

Weight : 4 lb (1.81 kg) Kilograms (kg)

Size : 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm)

Scale Range : A3150 Range 0150" w.c.

Dwyer A3040 Photohelic Pressure Switch Gauge Range 0-40 Inch w.c.

Dwyer A3040 Photohelic Pressure Switch Gauge Range 0-40 Inch w.c.

Price 40000 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Air and noncombustible, compatible gases

Weight : 4 lb (1.81 kg) Kilograms (kg)

Size : 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm)

Scale Range : A3040 Range 040" w.c.

Dwyer A3000-30KPA Photohelic Pressure Switch Gauge Range 0-30 kPa.

Dwyer A3000-30KPA Photohelic Pressure Switch Gauge Range 0-30 kPa.

Price 40000 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Air and noncombustible, compatible gases

Weight : 4 lb (1.81 kg) Kilograms (kg)

Size : 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm)

Scale Range : A300030KPA Range 030 kPa.



Back to top