Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c. Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c. Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c. Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c. Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c. Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.
Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.
Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c. Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c. Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c. Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c. Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.

Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.

40000 INR/Piece

Product Details:

  • Product Type Series A3000
  • Usage Air and non-combustible, compatible gases
  • Display 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm)
  • Size 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm)
  • Weight 4 lb (1.81 kg) Kilograms (kg)
  • Diameter 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm) Millimeter (mm)
  • Mount Type Surface
  • Click to View more
X

Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c. Price And Quantity

  • 40000 INR/Piece
  • 1 Piece

Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c. Product Specifications

  • 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm) Millimeter (mm)
  • Air and non-combustible, compatible gases
  • 4 lb (1.81 kg) Kilograms (kg)
  • 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm)
  • 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm)
  • A3030 Range 0-30" w.c.
  • Series A3000
  • Surface
  • Gas

Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c. Trade Information

  • Cash Against Delivery (CAD) Cash on Delivery (COD) Cash Advance (CA) Letter of Credit at Sight (Sight L/C) Telegraphic Transfer (T/T) Western Union Paypal Letter of Credit (L/C) Delivery Point (DP) Days after Acceptance (DA) Cash in Advance (CID) Cheque
  • EXTRA
  • Western Europe Australia North America Eastern Europe Central America Middle East South America Asia Africa
  • Assam Dadra and Nagar Haveli Chandigarh Himachal Pradesh Uttarakhand Lakshadweep South India Central India North India East India West India Andaman and Nicobar Islands Andhra Pradesh Arunachal Pradesh Bihar Delhi Daman and Diu Gujarat Goa Jammu and Kashmir Jharkhand Karnataka Maharashtra Mizoram Meghalaya Manipur Nagaland Punjab Pondicherry Rajasthan Sikkim Tamil Nadu Telangana Tripura Uttar Pradesh Haryana West Bengal Madhya Pradesh Kerala Odisha Chhattisgarh All India
  • YAS

Product Description

Dwyer A3030 Photohelic Pressure Switch Gauge Range 0-30 Inch w.c.
Dwyer A3030 Photohelic Pressure Switch/Gauge (0-30"w.c.)
Model: A3030

Bezel and front cover (with set point knobs and zero adjustment screw) removed to expose Photohelic® switch/gage set point mechanism. Cover is clear polycarbonate plastic. Gage pointer and light shutter are mounted on helix and balancing counterweight.

Dwyer A3030 Offers

Features

  • Measure 4 to 20 mA signals without "breaking the loop"
  • Measure mA signals for PLC and control system analog I/O
  • Dual backlit display with both mA measurement and percent of 4 to 20 mA span
  • Measurement Spotlight illuminates hard to see wires in dark enclosures
  • Detachable clamp with extension cable for measurements in tight locations
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
  • Automatically change the 4 to 20 mA output for remote testing
  • Power saving features, auto-off, backlight timeout extend battery life
  • Hold function captures and displays changing measurements

Applications

  • Air Conditioner Systems
  • Clean Rooms
  • Fume Exhaust Systems

Dwyer A3030 Specifications

Switch Specifications

  • Switch Type:Each set point has 2 Form C relays (DPDT)
  • Repeatability:±1% of FS
  • Electrical Rating:10 A at 28 VDC,10 A at 120,240 VAC
  • Electrical Connections:Screw terminals. Use 167°F (75°C) copper conductors only
  • Power Requirements:120 VAC, 50/60 Hz,240 VAC and 24 VAC power optional
  • Mounting Orientation:Diaphragm in vertical position. Consult factory for other position orientations
  • Set Point Adjustment:Adjustable knobs on face
  • Agency Approvals:CE, CSA, UL

Gauge Specifications

  • Service:Air and non-combustible, compatible gases
  • Accuracy:±2% of FS at 70°F (21.1°C),±3% on -0,±4% on -00 models
  • Pressure Limits:-20" Hg to 25 psig (-0.677 to 1.72 bar),MP option; 35 psig (2.41 bar),HP option; 80 psig (5.52 bar)
  • Temperature Limits:20 to 120°F. (-6.67 to 48.9°C),-20 to 120°F (-28 to 48.9°C) with low temperature option
  • Process Connections:? female NPT
  • Dimensions:4" (101.6 mm) dial face,5 x 8¼" (127 x 209.55 mm)
  • Weight:4 lb (1.81 kg)

Enter Buying Requirement Details
Email Id
Mobile number

Other Products in 'DWYER Series A3000 Photohelic Pressure Switch-Gage' category



Back to top