Dwyer 3000MRS Photohelic Switch/Gauge 0 to 60 Pa
Dwyer 3000MRS Photohelic Switch/Gauge 0 to 60 Pa

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 60 Pa

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 60 Pa Specification

  • Grade
  • Industrial
  • Thread
  • 1/8 NPT Female Connections
  • Outer Size
  • Approx. 116 mm Diameter (4-1/2 inch)
  • Seal Material
  • Silicone Rubber
  • Sensor Type
  • Photohelic Differential Pressure Sensor
  • Display
  • Analog Gauge with Setpoint Pointers and Visual Scale
  • Bourdon Tube
  • Not Applicable (Diaphragm Based)
  • Material
  • Die-cast Aluminum Case, Polycarbonate Cover
  • Dial Material
  • Polycarbonate
  • Pointer Material
  • Aluminum with Red Indicator
  • Processing Type
  • Precision Calibrated
  • Diameter
  • 116 mm (4-1/2 inch)
  • Glass Size
  • Full View Scale Window
  • Mount Type
  • Panel Mount or Surface Mount
  • Scale Range
  • 0 to 60 Pa
  • Accuracy
  • 2% of Full Scale
  • Finishing
  • Powder Coated and Polycarbonate Front Cover
  • Measure Pressure Of
  • Air and Compatible Gases
  • Accessories
  • Mounting Bracket, Instruction Manual
 

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 60 Pa Trade Information

  • Payment Terms
  • Cash Against Delivery (CAD), Cash on Delivery (COD), Cash Advance (CA), Cash in Advance (CID), Cheque
  • Main Export Market(s)
  • Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Asia, Africa
  • Main Domestic Market
  • All India
 

About Dwyer 3000MRS Photohelic Switch/Gauge 0 to 60 Pa

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 60 Pa

 Series 3000MR/3000MRS Photohelic® Switch/Gage

Combines Differential Pressure Gage with Low/High Set-Points,Compact Size

 

 ModelDescription 
 3000MRS-60 PaPressure Switch/Gage,Range 0-60 Pa, 2.0 minor divisions.
 

 

Includes

  • mounting ring, snap ring
  • 18" cable assembly
  • (2) 3/16" tubing to 1/8" NPT adapters
  • (2) 1/8" NPT pipe plugs
  • (4) 6-32 x 1-1/4" RH machine screws (panel mounting)
  • (3) 6-32 x 5/16" RH machine screws (surface mounting)

he Series 3000MR Photohelic® Switch/Gage combine the functions of a precise, highly repeatable differential pressure switch with a large easy-to-read analog pressure gage employing the durable, time-proven Magnehelic® gage design. Switch setting is easy to adjust with large external knobs on the gage face. Gage reading is unaffected by switch operation - will indicate accurately even if power is interrupted. Solid state design now results in greatly reduced size and weight. Units can be flush mounted in 4-13/16" hole or surface mounted with hardware supplied. 3000MR models employ versatile electromechanical relays with gold over silver contacts - ideal for dry circuits.

Gage accuracy is ±2% of full scale and switch repeatability is ±1%. Switch deadband is one pointer width - less than 1% of full scale. Compatible with air and other non-combustible, non-corrosive gases, they can be used in systems with pressures to 25 psig.

Applications

  • Fan Control
  • Damper Control
  • Environmental Pollution Control

Approvals

  • CE Approval
  • GOST-R Certificate

Specification

Service Air and non-combustible, compatible gases 
Accuracy ±2% of FS at 70°F 
Pressure Limits -20" Hg to 25 psig 
Temperature Limits 20 to 120°F 
Process Connections 1/8 female NPT (duplicated side and back) 
Size 4" dial face, 5" O.D. x 3-1/8" 
 Weight1.8 lb 
 Switch Specifications 
 Switch TypeEach setpoint has 1 Form C relay (SPDT) 
 Relay Contacts(resistive load) 1 Form C rated 1.0A @ 30 VDC, 0.3A @ 110 VDC or 0.5A @ 125 VAC. Gold over clad silver - suitable for dry circuits 
 Electrical Connections18" cable assembly with 8 conductors 
 Power Requirements24 VDC, regulated ±10% 
 Mounting OrientationDiaphragm in vertical position 
Set Point Adjustment Adjustable knobs on face 
 Agency ApprovalsCE 

  



Reliable Differential Pressure Measurement

The Dwyer 3000MRS combines advanced Photohelic differential pressure sensing with visual analog display and dual setpoint switches for accurate monitoring of air or compatible gases. Its diaphragm-based sensing mechanism ensures longevity and minimal maintenance, making it a staple in industrial-grade pressure control.


Versatile Installation and Operation

Designed for both panel and surface mounting, the 3000MRS fits seamlessly into a range of monitoring setups. Its die-cast aluminum case and polycarbonate front cover provide durability, while passive switches require no external power for the gauge, streamlining installation and reducing operational overhead.


Precision and Instant Response

With a measurement range of 0 to 60 Pa and 2% accuracy, the 3000MRS delivers high-precision readings. The dual adjustable SPDT switches operate instantaneously, ensuring prompt actuation for process control or alarming when preset thresholds are reached.

FAQs of Dwyer 3000MRS Photohelic Switch/Gauge 0 to 60 Pa:


Q: How do I install the Dwyer 3000MRS Photohelic Switch/Gauge in my system?

A: The 3000MRS can be mounted either on a panel or surface using the supplied mounting bracket. It connects via 1/8 NPT female thread ports and requires no power supply for basic gauge functionality. Refer to the instruction manual for wiring the SPDT switch outputs and proper orientation.

Q: What media is compatible with the 3000MRS sensor?

A: This model is designed for use with air or non-corrosive gases. Using it with other media may result in damage or inaccurate readings. The silicone rubber seals and polycarbonate materials ensure reliability with approved media.

Q: When should I use both setpoint switches on the 3000MRS?

A: The dual adjustable SPDT switches are ideal for applications requiring both high and low threshold detection, such as triggering alarms or control responses at two separate pressure points, enhancing safety and process monitoring.

Q: Where is the Dwyer 3000MRS best utilized?

A: The 3000MRS is widely used in HVAC systems, clean rooms, filter status monitoring, and other industrial settings in India where accurate differential pressure monitoring and switch control are required.

Q: What are the operational temperature limits of the 3000MRS?

A: This device operates reliably within a temperature range of -6.7C to 60C (20F to 140F), suitable for most indoor industrial environments.

Q: How does the Photohelic electronic switch operate without external power for the gauge?

A: The gauge is entirely passive and does not require external power. The two SPDT snap-acting switches respond mechanically to changes in pressure, offering fast response without additional energy input.

Q: What is the primary benefit of using a 3000MRS over a standard manometer?

A: The 3000MRS provides not just pressure measurement but also electronic switching capabilities, enabling automated control or alarm functions directly from the gauge, which simplifies system design and improves process reliability.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Dwyer Series 3000MR/3000MRS Photohelic Switch-Gage Category

Dwyer 3030MRS Photohelic Switch/Gauge 0 to 30 inch

Dwyer 3030MRS Photohelic Switch/Gauge 0 to 30 inch

Mount Type : Other, Surface or Panel Mount

Display : Analog

Accuracy : 2% of Full Scale

Pointer Material : Aluminum

Scale Range : 0 to 30 inch WC

Finishing : Other, Powder Coated

Dwyer 3000MR-00 Photohelic Differential Pressure Switch/Gauge Range: 0-0.25

Dwyer 3000MR-00 Photohelic Differential Pressure Switch/Gauge Range: 0-0.25" w.c.

Mount Type : Other, Flush or Surface Mount

Display : Analog & Digital

Accuracy : 2% of full scale

Pointer Material : Aluminum

Scale Range : 00.25 w.c.

Finishing : Other, Powder coated housing

Dwyer 3020MRS Photohelic,Switch/Gauge 0 to 20 in W.C

Dwyer 3020MRS Photohelic,Switch/Gauge 0 to 20 in W.C

Mount Type : Other, Panel Mount

Display : Analog

Accuracy : 2% of full scale

Pointer Material : Other, Metal

Scale Range : 0 to 20 in W.C. (inches Water Column)

Finishing : Other, Black epoxycoated housing

Dwyer 3000MR Photohelic,Switch/Gauge 0 to 60 PAC

Dwyer 3000MR Photohelic,Switch/Gauge 0 to 60 PAC

Mount Type : Other, Panel Mount or Surface Mount

Display : Analog Dial

Accuracy : 2% of Full Scale

Pointer Material : Aluminum

Scale Range : 0 to 60 Pa (Pascal)

Finishing : Other, Black Textured Finish



Back to top